2018
DOI: 10.1515/ijame-2018-0013
|View full text |Cite
|
Sign up to set email alerts
|

Identification of the Cause of the Stem Neck Fracture in the Hip Joint Endoprosthesis

Abstract: Endoprosthesis stem fractures are among the rarest complications that occur after hip joint arthroplasty. The aim of this paper is to evaluate the causes of the fractures of the Aura II stem neck, which is an element of an endoprosthesis implanted in a patient. In order to achieve it, a radiogram was evaluated, the FEM analysis was carried out for the hip joint replaced using the Aura II prosthesis and scanning tests as well as a chemical analysis were performed for the focus of fatigue. The tests performed in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 23 publications
(19 reference statements)
0
1
0
Order By: Relevance
“…18 , 25 , 26 , 27 , 28 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 30 cases to the surgeon (i.e., electrocautery contact to the implant, incorrect handling of implant, etc.) 30 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , and 22 cases to the patient (i.e., bone loss, tissue reaction, BMI, trauma) 9 , 17 , 5665 . One hundred and ten cases resulted out of a mixture of the three given causes for failure 13 , 15 , 29 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 .…”
Section: Resultsmentioning
confidence: 99%
“…18 , 25 , 26 , 27 , 28 , 31 , 32 , 33 , 34 , 35 , 36 , 37 , 38 , 39 , 40 , 41 , 30 cases to the surgeon (i.e., electrocautery contact to the implant, incorrect handling of implant, etc.) 30 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 55 , and 22 cases to the patient (i.e., bone loss, tissue reaction, BMI, trauma) 9 , 17 , 5665 . One hundred and ten cases resulted out of a mixture of the three given causes for failure 13 , 15 , 29 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 .…”
Section: Resultsmentioning
confidence: 99%
“…Other applications include the determination of fracture surface morphology, phase distribution and arrangement within the fracture surface. This method can be successfully used for reverse analysis, where the fracture surface morphology helps to deduce not only the cause of the component failure, but also gives answers to the change of the semi-product behavior during the technological process [6][7][8].…”
Section: Introductionmentioning