2022
DOI: 10.3390/jcm11237124
|View full text |Cite
|
Sign up to set email alerts
|

Identification of Neural Mechanisms in First Single-Sweep Analysis in oVEMPs and Novel Normative Data

Abstract: Background: Bone-conducted (BC) VEMPs provide important tools for measuring otolith function. However, two major drawbacks of this method are encountered in clinical practice—small n10 amplitude and averaging technique. In this study, we present the results of a new VEMP setup measuring technique combined with a novel single-sweep analysis. Methods: The study included BC oVEMP data from 92 participants for the evaluation of normative data using a novel analysis technique. For evaluating test-retest reliability… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…Vanspauwen et al compared the ICC for N1 and P1 between the standard electrode montage and a modified belly tendon montage derived from Sandhu et al, revealing higher ICC for the clinical standard (35,36). Even with newly adapted electrode montages or oVEMP stimuli, values of ICC for the clinical standard remained on the level of previous studies while the two newly introduced electrode montages N and L showed higher levels of reliability (15,36,54). Vanspauwen explains the rather low values of ICC for latencies in the context of the ICC's calculation method and the small size of the dataset.…”
Section: Reliability Of Ovemp Measurements Compared Withmentioning
confidence: 96%
See 2 more Smart Citations
“…Vanspauwen et al compared the ICC for N1 and P1 between the standard electrode montage and a modified belly tendon montage derived from Sandhu et al, revealing higher ICC for the clinical standard (35,36). Even with newly adapted electrode montages or oVEMP stimuli, values of ICC for the clinical standard remained on the level of previous studies while the two newly introduced electrode montages N and L showed higher levels of reliability (15,36,54). Vanspauwen explains the rather low values of ICC for latencies in the context of the ICC's calculation method and the small size of the dataset.…”
Section: Reliability Of Ovemp Measurements Compared Withmentioning
confidence: 96%
“…These results may suggest that, besides statistical reasons and measures for standardization, the use of electrode montage N and L also had a positive impact on reliability. Further optimization of reliability for adults could be achieved in future studies using bone-conducted vibration or new trigger designs as compared by Reddy et al (9,15,33).…”
Section: Reliability Of Ovemp Measurements Compared Withmentioning
confidence: 99%
See 1 more Smart Citation