2000
DOI: 10.1016/s0379-0738(00)00256-5
|View full text |Cite
|
Sign up to set email alerts
|

Identification of lorazepam and sildenafil as examples for the application of LC/ionspray-MS and MS–MS with mass spectra library searching in forensic toxicology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
21
0

Year Published

2000
2000
2011
2011

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(22 citation statements)
references
References 7 publications
1
21
0
Order By: Relevance
“…MS/MS libraries with CID-spectra of the quasimolecular ions can be very useful for this purpose. Therefore, MS/MS libraries of drugs have been developed using triple-quadrupole instruments [9,10]. Besides these MS/MS libraries, a procedure using MS/MS and MS 3 spectra libraries with ion-trap detectors using wideband excitation has been developed for general-unknown screening [11][12][13][14], including the use of data dependent experiments (DDE).…”
Section: Introductionmentioning
confidence: 99%
“…MS/MS libraries with CID-spectra of the quasimolecular ions can be very useful for this purpose. Therefore, MS/MS libraries of drugs have been developed using triple-quadrupole instruments [9,10]. Besides these MS/MS libraries, a procedure using MS/MS and MS 3 spectra libraries with ion-trap detectors using wideband excitation has been developed for general-unknown screening [11][12][13][14], including the use of data dependent experiments (DDE).…”
Section: Introductionmentioning
confidence: 99%
“…HPLC 5) and LC-MS 6) techniques have been reported to date as analytical methods for the determination of SDF and/or its metabolites in biological samples. However, no GC-MS method for SDF has been reported so far, probably because in addition to their thermolability, it is difficult to derivatize SDF analogies with standard silylation reagents.…”
mentioning
confidence: 99%
“…A number of papers have been published discussing the MS detection of LOR in HPLC [20][21][22][23][24] or CE [31,32]. In these approaches, LOR was detected as a positive ion.…”
Section: Previous Work and Analysis Of Lor And Lor-3o-glucuronide By mentioning
confidence: 99%
“…The confirmation of the presence of LOR and structurally related compounds in body fluids is performed by GC with electron capture [11] or MS detection [16,18], by HPLC with UV [19] or MS [20][21][22][23][24] detection, and by MEKC with UV detection [13,25]. Much less has been published concerning the analysis of LOR-3O-glucuronide.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation