1974
DOI: 10.1021/ac60338a045
|View full text |Cite
|
Sign up to set email alerts
|

Identification of heroin and its diluents by chemical ionization mass spectroscopy

Abstract: Preprocessing technique Classification method Autoscale Weighted autoscale Optimum linear transformation I. Linear classifier a) Least-squares 83/83 83/83 83/83 b) Negative feedback 56/83 77/70 74/87 II. 3-Nearest Neighbor 80/60 89/80 92/97 III. Multiclass classifier a) Least-squares 91/87 91/87 91/87 b) Negative feedback 94/90 93/90 78/90method is invariant to all linear transformations, the results are the same for the three preprocessed sets of mass spectral data.The second classification method used in thi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0

Year Published

1978
1978
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(11 citation statements)
references
References 8 publications
0
11
0
Order By: Relevance
“…Because isobutane reagent ions have a significantly higher proton affinity than methane reagent ions, analyte fragmentation upon proton transfer from a reagent ion is reduced or eliminated, and the abundance of the intact adduct ion is increased. Isobutane has been used for applications where it was critical to identify the analyte protonated molecule and for maximum sensitivity [10][11][12][13][14][15][16]. Isobutane is also more efficient at creating thermal electrons than methane [7] and has been used for increased EC-NCI analyte signal [17].…”
Section: Introductionmentioning
confidence: 99%
“…Because isobutane reagent ions have a significantly higher proton affinity than methane reagent ions, analyte fragmentation upon proton transfer from a reagent ion is reduced or eliminated, and the abundance of the intact adduct ion is increased. Isobutane has been used for applications where it was critical to identify the analyte protonated molecule and for maximum sensitivity [10][11][12][13][14][15][16]. Isobutane is also more efficient at creating thermal electrons than methane [7] and has been used for increased EC-NCI analyte signal [17].…”
Section: Introductionmentioning
confidence: 99%
“…Heroin would best be quantitated in HC1 solutions at 238 nm, [9] = +64. The [9] values for 6-MAM and morphine at the same wavelength are +270 and +311, respectively (12). In base, [9] for morphine at the band maximum at 253 nm is +458.…”
Section: Resultsmentioning
confidence: 89%
“…The [9] values for 6-MAM and morphine at the same wavelength are +270 and +311, respectively (12). In base, [9] for morphine at the band maximum at 253 nm is +458. The results from the four analytical procedures which involve CD, and the GC results are given in Table I as percent heroin free base by weight in the confiscates.…”
Section: Resultsmentioning
confidence: 89%
See 2 more Smart Citations