2020
DOI: 10.1016/j.talanta.2020.121198
|View full text |Cite
|
Sign up to set email alerts
|

Identification of additives in polymers from single-use bioprocessing bags by accelerated solvent extraction and ultra-high performance liquid chromatography coupled with high-resolution mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 31 publications
0
4
0
Order By: Relevance
“…Accelerated solvent extraction with gas chromatography mass spectrometry (ASE GC-MS) An organic additive screen was conducted on all substrates using previously established methods utilizing GC-MS with minor adjustments. 37,125 For GC-MS analysis, accelerated solvent extraction (ASE) was conducted using a Model ASE 200 (Dionex, Germany). 500 mg to 1 g of cryomilled sample was mixed with diatomite to fill an ASE extraction cell.…”
Section: Fluorine Analysismentioning
confidence: 99%
“…Accelerated solvent extraction with gas chromatography mass spectrometry (ASE GC-MS) An organic additive screen was conducted on all substrates using previously established methods utilizing GC-MS with minor adjustments. 37,125 For GC-MS analysis, accelerated solvent extraction (ASE) was conducted using a Model ASE 200 (Dionex, Germany). 500 mg to 1 g of cryomilled sample was mixed with diatomite to fill an ASE extraction cell.…”
Section: Fluorine Analysismentioning
confidence: 99%
“…To determine whether OPEs were exhaustively extracted from the SHLB packaging material, ASE was further employed for comparison with water and hexane extractions. 30 Hexane and dichloromethane (1:1, v/v) were used for the extraction of packaging materials (n = 3) at a temperature of 120 °C and a pressure of 10.3 MPa, with two static cycles and a purge time of 120 s. The following procedures were identical to those performed for hexane extraction.…”
Section: Migration and Extractionmentioning
confidence: 99%
“…214 Various scoring algorithms are available, and their selection and implementation are known to affect predictivity, 215 though specific algorithms and settings are often unreported. Dot-product-based scoring methods (e.g., as in the NIST 1A GC/MS library 83,97,216 ) that are based on the number of matching fragment ions and the sum of intensity differences can be used to calculate the match score. 217 For LC/MS, the use of public databases such as MassBank and mzCloud 83 have been reported.…”
Section: ■ Extractionmentioning
confidence: 99%