2015
DOI: 10.1016/j.chroma.2015.01.048
|View full text |Cite
|
Sign up to set email alerts
|

Identification and semi-quantitative determination of anti-oxidants in lubricants employing thin-layer chromatography-spray mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0
2

Year Published

2015
2015
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 26 publications
0
10
0
2
Order By: Relevance
“…The TLC plates are cut to sharp point and an electrospray is induced from the tip. Aluminum backed TLC plates, which are easy to cut, have been the most widely used to date [65][66][67][68]. The TLC plate can be coupled directly to the MS in an online mode [65].…”
Section: Thin Layer Chromatography Platesmentioning
confidence: 99%
See 1 more Smart Citation
“…The TLC plates are cut to sharp point and an electrospray is induced from the tip. Aluminum backed TLC plates, which are easy to cut, have been the most widely used to date [65][66][67][68]. The TLC plate can be coupled directly to the MS in an online mode [65].…”
Section: Thin Layer Chromatography Platesmentioning
confidence: 99%
“…Another option is to perform the TLC separation offline and cut the bands out in a triangle shape. Extraction and ionization can then be done directly from the removed portion of the TLC plate [68].…”
Section: Thin Layer Chromatography Platesmentioning
confidence: 99%
“…续地洗脱分析物 [92] . 最近发展的TLC电喷雾电离技术, TLC板上预分离的样品点剪切成三角形的小片再加 试剂提取样品并产生喷雾电离 [93,94] . 施加的试剂作为 洗脱液和喷雾试剂, 样品逐个洗脱和喷出进入质谱检 测 [86] , 如图2(c)所示.…”
Section: 早期的研究Tlc板通过板后开槽加入流动相可以持unclassified
“…Coupling of TLC with MS has attracted much attention [20,21], and various ionization methods, including fast atom bombardment (FAB) [22,23], matrixassisted laser desorption/ionization (MALDI) [24] ionization methods such as liquid extraction junction [25][26][27], desorption electrospray ionization (DESI) [28,29], direct analysis in real time (DART) [30][31][32], easy ambient sonic-spray ionization (EASI) [33] and electrospray laser desorption ionization (ELDI) [34], have been employed for the coupling. In addition, direct coupling of TLC with ESI, in which separated sample spots were cut out for directly ESI or samples were separated online and then directly sprayed out, was also demonstrated [35][36][37]. However, the major purposes of these coupling studies were to facilitate identification of the separated TLC spots by MS or online separation and detection of compounds in simple mixtures.…”
Section: Introductionmentioning
confidence: 98%