2007
DOI: 10.1016/j.chroma.2007.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Identification and quantification of alkene-based drilling fluids in crude oils by comprehensive two-dimensional gas chromatography with flame ionization detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
43
0
1

Year Published

2007
2007
2020
2020

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 57 publications
(45 citation statements)
references
References 18 publications
1
43
0
1
Order By: Relevance
“…4) exhibited a dominance of C 16 and C 18 (Fig. 5), identified by the 2D gas chromatograph (GC×GC) time-of-flight (TOF) mass spectrometer, which unambiguously traces olefins stemming from drilling mud (49,50). These olefins fell below the detection limit in 2011.…”
Section: Resultsmentioning
confidence: 99%
“…4) exhibited a dominance of C 16 and C 18 (Fig. 5), identified by the 2D gas chromatograph (GC×GC) time-of-flight (TOF) mass spectrometer, which unambiguously traces olefins stemming from drilling mud (49,50). These olefins fell below the detection limit in 2011.…”
Section: Resultsmentioning
confidence: 99%
“…Admittedly, the dinaphthenes were less ordered than the linear and mononaphthenic alkanes, presumably because of the increasing number of isomers present (5-and 6-membered naphthenic rings and cis/trans isomerism). A-E, mono-naphthenes C 10 -C 14 ; F-J, di-naphthenes C 10 -C 13 [141,142] GCÂGC-FID was also used for the quantification of internal olefin or linear α-olefin contamination in petroleum samples [146]. With separate fine-tuned temperature programmes for the two columns, a 7.5 m Rtx-1 Â 2 m BPX-50 column set yielded a fully acceptable separation of the alkene-based components in crude oils; C 15 -C 18 and C 20 alkenes were determined.…”
Section: Petrochemical Analysismentioning
confidence: 99%
“…According to the chemical properties of the different compounds, the software can classify them into certain groups, generating the corresponding number and peak area in the peak table. In the data processing results of GC × GC-FID, because the response factor of the FID detector toward all the hydrocarbons was close to 1 [40][41][42], the quantification of compounds was achieved by means of peak area normalization. This means the ratio between the area of one certain compound and the total area of all the aromatic hydrocarbons equals the weight percentage of this compound.…”
Section: Quantitative Methodsmentioning
confidence: 99%