1997
DOI: 10.1109/61.634210
|View full text |Cite
|
Sign up to set email alerts
|

Identification and modelling of a three phase arc furnace for voltage disturbance simulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
36
0
4

Year Published

2010
2010
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 109 publications
(40 citation statements)
references
References 4 publications
0
36
0
4
Order By: Relevance
“…Aurelio García-Cerrada et al [5] has compared the performance of TCR based and VSI based flicker compensation experimentally from the arc furnace installation. An electrical arc furnace is a stochastic non linear load [6].The author has proposed a model for an arc furnace by assuming that whenever there is current, the voltage drop is constant for fixed for fixed arc length.…”
Section: Vmentioning
confidence: 99%
“…Aurelio García-Cerrada et al [5] has compared the performance of TCR based and VSI based flicker compensation experimentally from the arc furnace installation. An electrical arc furnace is a stochastic non linear load [6].The author has proposed a model for an arc furnace by assuming that whenever there is current, the voltage drop is constant for fixed for fixed arc length.…”
Section: Vmentioning
confidence: 99%
“…baskets of steel) with variable transformer taps (tap 6, 7, and 9) and fixed reactor tap (4). Figures 7 to 10 show the comparison between the measured and the simulated data for the arc resistances and reactances, the powers (apparent, active, arc and reactive) and the power factors for all three phases.…”
Section: Electrical Modelmentioning
confidence: 99%
“…There are already a number of papers that present various modeling approaches to several sub-systems of electric arc furnaces, from basic arc models 1,2) to complex flicker simulations, [3][4][5][6][7] which tend to prevail due to the enormous impact of EAFs on electrical networks. Since the EAF represents a complex system these articles usually focus on a certain EAF-related problem and in some instances use simulated, laboratory-generated data for the analysis, which is easier to process and gives more convenient results.…”
Section: Introductionmentioning
confidence: 99%
“…Electric arc furnace, the main generator of voltage flicker, behaves in the form of a constant reactance and a variable resistance. of 0.26% R. Collantes-Bellido et al [3] have analysed about the Identification and Modeling of a Three Phase Arc Furnace for Voltage Distribution Simulation in his paper "voltage flicker compensationusing statcom" [3].The author concluded that the conceptof Huge non-linear industrial loads such as the electrical arc furnacespumps, welding machines, rolling mills andothers are known as flicker generators.…”
Section: Introductionmentioning
confidence: 99%