TENCON 2009 - 2009 IEEE Region 10 Conference 2009
DOI: 10.1109/tencon.2009.5395952
|View full text |Cite
|
Sign up to set email alerts
|

Identification and analysis of operating modes of single-phase semi-converter fed battery charging circuits using extinction angle control scheme — A monograph

Abstract: A system of 1-phase semi-converter fed battery charging circuit meant for being supplied from a self-excited induction generator is analysed with Extinction Angle Control (EAC) scheme. Several modes of operation of this scheme with continuous as well as discontinuous load current have been identified and the input and output voltage and current wave forms for each one of them have been depicted. Starting from the circuit equations, all these modes have been studied and expressions for the various performance q… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 8 publications
(8 reference statements)
0
2
0
Order By: Relevance
“…In addition, the worst even harmonic magnitude is produced when the firing angle is around 90° [20]. Applications of this topology are for DC welding, electroplating, battery charging [21], and some DC drives [22].…”
Section: Even Harmonic Sourcesmentioning
confidence: 99%
“…In addition, the worst even harmonic magnitude is produced when the firing angle is around 90° [20]. Applications of this topology are for DC welding, electroplating, battery charging [21], and some DC drives [22].…”
Section: Even Harmonic Sourcesmentioning
confidence: 99%
“…Even in advanced text books and papers dealing with such topics, only one case of discontinuous current [5][6][7][8][9] has 978-1-4799-6805-3/15/$31.00 ©2015 IEEE been described. But, the present authors have earlier analysed the operation of single-phase semi-converters with various firing schemes, identified the various current patterns and derived expressions for the various performance quantities such as average dc voltage, total rms and fundamental rms components of ac supply current for each pattern called as a mode [10][11][12]. Such a rigorous analysis is now made for the three-phase semi-converters, activated with Phase Angle Control scheme (PAC) and supplying batteries.…”
Section: List Of Symbolsmentioning
confidence: 99%