IAEA proficiency tests for determination of radionuclides in sea water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2017
2017
2018
2018

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(8 citation statements)
references
References 3 publications
0
8
0
Order By: Relevance
“…0.768 mBq L -1 , 0.866 mBq L -1 and 0.826 mBq L -1 which were 0 %,  12.76 % and  7.55 % bias for 200 L, 300 L and 600 L respectively as referred to the AMP pre-concentration method result from the PT exercise [2]. Even the minimum and maximum activity concentrations i.e.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…0.768 mBq L -1 , 0.866 mBq L -1 and 0.826 mBq L -1 which were 0 %,  12.76 % and  7.55 % bias for 200 L, 300 L and 600 L respectively as referred to the AMP pre-concentration method result from the PT exercise [2]. Even the minimum and maximum activity concentrations i.e.…”
Section: Resultsmentioning
confidence: 99%
“…The method to determine activity concentration of 137 Cs in seawater samples using AMP preconcentration method passed the proficiency test exercise, "IAEA proficiency test exercise on Marine benchmark study on the possible impact of the Fukushima radioactive releases in the Asia-Pacific Region for Caesium Determination in Sea Water (RCA RAS/7/021)", for accuracy, precision and trueness criteria with -1.00 % bias [2]. The same method was applied to determine 137 Cs in seawater in this analysis and result is shown in table 1.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The relative bias (RB) was the first step in producing a score for a result Value Analyst. RB between the Analyst's value and the IAEA target value was calculated and expressed as a percentage according to equation (1).…”
Section: Data Evaluationmentioning
confidence: 99%
“…The PT results judged were based on IAEA criteria using different statistic evaluation criterion such as accuracy, precision and trueness as follow [1,[6][7]; 2.4.1. Accuracy.…”
Section: Data Evaluationmentioning
confidence: 99%