1997
DOI: 10.1107/s0021889897003543
|View full text |Cite
|
Sign up to set email alerts
|

STRATEGY: a program to optimize the starting spindle angle and scan range for X-ray data collection

Abstract: STRATEGY is a program for determination of the optimal starting spindle angle and scan range for X-ray diffracton data collection. It is optimized for crystals of macromolecular compounds using a one-circle diffractometer with a twodimensional detector. In its current implementation, the program reads the starting crystal orientation and cell parameters from a DENZO intensities '.x' file and simulates all the reflections that can occur during a 360 ° rotation of the crystal. It determines whether the reflectio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
52
0

Year Published

1998
1998
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 67 publications
(52 citation statements)
references
References 4 publications
(4 reference statements)
0
52
0
Order By: Relevance
“…The conformational changes observed on complexation are likely not induced by the crystal packing because they are identical in the two different crystal forms. Furthermore, we have recorded 15 N heteronuclear sequential quantum correlation spectra of CSPMbraA6 alone or in complex with BrC12OH (13). The superimposition of the spectra of the apo and complexed protein spectra has revealed Ͼ50% changes in the peak displacements, indicating that the extensive conformational changes observed in the crystal also occur in solution (13).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The conformational changes observed on complexation are likely not induced by the crystal packing because they are identical in the two different crystal forms. Furthermore, we have recorded 15 N heteronuclear sequential quantum correlation spectra of CSPMbraA6 alone or in complex with BrC12OH (13). The superimposition of the spectra of the apo and complexed protein spectra has revealed Ͼ50% changes in the peak displacements, indicating that the extensive conformational changes observed in the crystal also occur in solution (13).…”
Section: Discussionmentioning
confidence: 99%
“…A single wavelength anomalous diffraction dataset was collected on ID-29 at the European Synchrotron Radiation Facility (Grenoble) at the Br-K edge ( ϭ 0.91965 Å, maximum f Љ; Table 1). Data were collected from a single crystal in an arbitrary setting by using a ADSC (Poway, CA) Quantum 4 detector after optimizing the oscillation range by using STRATEGY (15). All data were processed and reduced by using DENZO (16) and the CCP4 program suite (17).…”
Section: Methodsmentioning
confidence: 99%
“…There are no good excuses for collecting data that are incomplete. There exist many programs which, following autoindexing of the ®rst image, will predict the optimum 9 range to collect and the 9 value at which to start data collection so that the completeness is maximized using the minimum beamtime (Leslie, 1993;Kabsch, 1993;Noble, 1996;Otwinowski & Minor, 1997;Ravelli et al, 1997). Table 1 shows the contrast between the 9 ranges for optimized data collection (Dauter, 1999) and that required in the worst-case scenario (crystal aligned with the lowest symmetry axis parallel to the beam and starting the 9 rotation from the worst possible place).…”
Section: Poor Diffraction And/or Incomplete Anomalous Datamentioning
confidence: 99%
“…Data were collected on ID14-EH2 ( ϭ 0.933 Å) using the STRATEGY program (17) to determine the angular range for collection. For the time course experiment, a series of data sets were measured over the same oscillation range.…”
Section: Cloning Expression and Purification Of Recombinant Tryparementioning
confidence: 99%