2017
DOI: 10.1093/bioinformatics/btx458
|View full text |Cite
|
Sign up to set email alerts
|

proFIA: a data preprocessing workflow for flow injection analysis coupled to high-resolution mass spectrometry

Abstract: Supplementary data are available at Bioinformatics online.

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(10 citation statements)
references
References 42 publications
0
10
0
Order By: Relevance
“…Once the peak lists have been extracted from each file, alignment of the features between the samples is performed by using a kernel Gaussian density ( Delabrière et al , 2017 ; Smith et al , 2006 ). Two quality control steps may then be applied to select features (i) with a high reproducibility between samples (alternatively between classes of samples), and/or (ii) labeled as ‘exhaled breath’ in the majority of samples (by thresholding the P -value of the statistical tests described above).…”
Section: Methodsmentioning
confidence: 99%
“…Once the peak lists have been extracted from each file, alignment of the features between the samples is performed by using a kernel Gaussian density ( Delabrière et al , 2017 ; Smith et al , 2006 ). Two quality control steps may then be applied to select features (i) with a high reproducibility between samples (alternatively between classes of samples), and/or (ii) labeled as ‘exhaled breath’ in the majority of samples (by thresholding the P -value of the statistical tests described above).…”
Section: Methodsmentioning
confidence: 99%
“…Single acquisition Orbitrap mass spectra (no averaging) were acquired at a resolution of 500 000 (FWHM, m / z 200) with an automatic gain control (AGC) of 2 × 10 5 and a maximum injection time of 100 ms (typically ion injection times were about 2 ms, and they rarely surpassed 10 ms because the AGC target had already been reached). Data evaluation was performed with the proFIA tool described by Thevenot and coworkers 42 …”
Section: Methodsmentioning
confidence: 99%
“…proFIA is an R package that implements several novel algorithms to preprocess Flow Injection Analysis coupled to High‐Resolution Mass Spectrometry (FIA‐HRMS) workflows for high throughput metabolomics studies . The tool performs noise estimation, peak detection and quantification, peak grouping across samples, and missing value imputation among other functionalities.…”
Section: Tools For Data Analysismentioning