2020
DOI: 10.1080/02656736.2020.1800831
|View full text |Cite
|
Sign up to set email alerts
|

In vivo magnetic nanoparticle hyperthermia: a review on preclinical studies, low-field nano-heaters, noninvasive thermometry and computer simulations for treatment planning

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
65
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 63 publications
(65 citation statements)
references
References 184 publications
(280 reference statements)
0
65
0
Order By: Relevance
“…However, rather than adopting a general or macroscopic view of this issue, we shall focus on the cellular and subcellular effects of this treatment. There are many in vitro and in vivo studies that have correlated MNPs and AMF therapies with extended life expectancy or tumour regression [ 131 ], although the biochemical mechanisms responsible for such improvements remain unclear. Depending on the magnetic features of the MNPs, and on the AMF amplitude and frequency, the MNPs can transform the energy of the magnetic field into heat or mechanical effects ( Figure 2 c, d, e).…”
Section: The Biological Effects Of the Application Of Afm To Cells Loaded With Mnps: Is It Always Hyperthermia?mentioning
confidence: 99%
“…However, rather than adopting a general or macroscopic view of this issue, we shall focus on the cellular and subcellular effects of this treatment. There are many in vitro and in vivo studies that have correlated MNPs and AMF therapies with extended life expectancy or tumour regression [ 131 ], although the biochemical mechanisms responsible for such improvements remain unclear. Depending on the magnetic features of the MNPs, and on the AMF amplitude and frequency, the MNPs can transform the energy of the magnetic field into heat or mechanical effects ( Figure 2 c, d, e).…”
Section: The Biological Effects Of the Application Of Afm To Cells Loaded With Mnps: Is It Always Hyperthermia?mentioning
confidence: 99%
“…4 In silico experiments are performed to estimate the Specific Adsorption Rate (SAR) and temperature increase under critical conditions, to provide safety advise for preclinical trials, sometime performed without fulfilling the Hergt-Dutz limit. 5 The results obtained on a 28 g weight mouse 3…”
Section: Resultsmentioning
confidence: 99%
“…The proposed system successfully localized MNPs, provided real-time 2D temperature maps during MH, and qualitatively predicted the temperature distribution in MNP-laden regions. Because SPIONs are used in MMUS and tissues have temperature-dependent elastic properties, MMUS can also be used for thermometry during MH 147 . Various electromagnetic-acoustic techniques, such as magnetomotive photoacoustic imaging (MMPA), have also been proposed for theranostic applications.…”
Section: Magnetoacoustic Imagingmentioning
confidence: 99%