2014
DOI: 10.3109/03639045.2014.947506
|View full text |Cite
|
Sign up to set email alerts
|

In vivoevaluation of a mucoadhesive polymeric caplet for intravaginal anti-HIV-1 delivery and development of a molecular mechanistic model for thermochemical characterization

Abstract: The obtained results, which were corroborated by MM simulations, attested that the developed system has the potential for effective delivery of anti-HIV-agents.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
6
0
4

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 47 publications
2
6
0
4
Order By: Relevance
“…As depicted in Figure 2d, the presence of absorption peaks at 1100 and 430 cm −1 in GOPS‐treated samples can be assigned to the Si–O–Si absorption 49,50. Furthermore, the vibrational absorption peaks of –SO 3 groups (995–1125 cm −1 )51,52 upon the addition of GOPS confirmed the interactions between –SO 3 groups and GOPS, which is in accordance with the XPS results.…”
Section: Photovoltaic Performances Of Inverted Single Junction and Hosupporting
confidence: 85%
“…As depicted in Figure 2d, the presence of absorption peaks at 1100 and 430 cm −1 in GOPS‐treated samples can be assigned to the Si–O–Si absorption 49,50. Furthermore, the vibrational absorption peaks of –SO 3 groups (995–1125 cm −1 )51,52 upon the addition of GOPS confirmed the interactions between –SO 3 groups and GOPS, which is in accordance with the XPS results.…”
Section: Photovoltaic Performances Of Inverted Single Junction and Hosupporting
confidence: 85%
“…Two peaks appear at 1466 cm -1 and 1352 cm -1 are due to CH2 scissoring and CH bending respectively. The FTIR spectra of polyamide-11 ( Fig.8) almost exactly coherent with the spectrum of polyamide-6 given in literature [20][21][22]. FTIR spectra of primer shows a broad weak peak at 3271 cm -1 due to the N-H stretching and CH2 stretching show peak at 2926 cm -1 (Fig.9).…”
Section: 3chemical Composition and Structure Analysissupporting
confidence: 84%
“…In the case of copolyamide, the peak at 3288 cm −1 represents the N-H stretching vibration. Two peaks at 2923 cm −1 and 2854 cm −1 represent the asymmetric -CH2 stretching and symmetric -CH2 stretching, respectively [32]. The band at 1637 cm −1 represents the -C=O stretching vibration.…”
Section: Fourier Infrared Spectroscopy (Ftir) Analysismentioning
confidence: 99%