2015
DOI: 10.1155/2015/391040
|View full text |Cite
|
Sign up to set email alerts
|

Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions

Abstract: This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems. Several harmonic suppression techniques have been widely proposed and applied to minimize harmonic effects. The proposed control scheme can compensate harmonics and reactive power of the nonlinear loads simultaneously. This approach is compared to the conventional shunt APF reference compensation … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
2

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(11 citation statements)
references
References 12 publications
(19 reference statements)
0
9
0
2
Order By: Relevance
“…• The result obtained on one current is not independent of the other two phases. Thus, the enslaved current cannot respect the limits imposed by the band of hysteresis [9].…”
Section: Some Disadvantages Arementioning
confidence: 99%
See 1 more Smart Citation
“…• The result obtained on one current is not independent of the other two phases. Thus, the enslaved current cannot respect the limits imposed by the band of hysteresis [9].…”
Section: Some Disadvantages Arementioning
confidence: 99%
“…However, the active filter is an effective way to overcome harmonic pollution [9]. Through this contribution we will seek to study a system consisting of a photovoltaic generator and a parallel active filter.…”
Section: Introductionmentioning
confidence: 99%
“…A partir de esta formulación, se ha propuesto la estimación de la referencia de corriente para compensadores paralelo denominada cancelación perfecta de armónicos (PHC, por sus siglas en inglés) dada por la ecuación (8).…”
Section: U⃗ (U⃗⨂⃗ I) U⃗ + P(t) U⃗ + Q(t) U⃗ U⃗u⃗ U⃗u⃗ U⃗u⃗unclassified
“…Los dispositivos CPD más comunes son el filtro activo paralelo para compensar corriente y factor de potencia [7], [8] y el filtro activo serie para compensar tensión armónica, SAG y SWELL. Uno de los dispositivos CPD más eficientes consta de un filtro activo serie y uno paralelo con un bus DC común, que es llamado acondicionador unificado de calidad de la potencia UPQC [1], [9], [10].…”
Section: Introductionunclassified
“…In [9,10], it transforms the harmonic component to the DC component through multisynchronous rotating coordinate transformation; thus, traditional PI controller can be utilized to track the harmonics with zero steady-state error; however, it is too complicated. e hysteresis current control method presented in [11,12] with quickly dynamic respond performance is simple and easy to realize without carrier modulation, but the control accuracy is inversely proportional to switching frequency. In addition, the switching frequency is not fixed, which sets a higher request to switching device.…”
Section: Introductionmentioning
confidence: 99%