2021
DOI: 10.1016/j.avsg.2020.10.040
|View full text |Cite
|
Sign up to set email alerts
|

Hypogastric Artery Salvage Using an Unibody Bifurcated Aorto-Iliac Graft Associated to Double-Barrel Technique in Spontaneous Isolated Abdominal Aortic Dissection.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…19,20 The unibody anatomical features allowed to guarantee subsequent possibility for cross-over interventions and to perform endovascular reconstructions especially when the reentry zone distally to an obstruction was located nearly an arterial bifurcation. 21 We straightened the concept of hypogastric salvage for several concepts. First, hypogastric salvage may be necessary in extensive aortic coverage especially in aortic reinterventions and during inferior mesenteric artery coverage for bowel ischemia prevention.…”
Section: Discussionmentioning
confidence: 99%
“…19,20 The unibody anatomical features allowed to guarantee subsequent possibility for cross-over interventions and to perform endovascular reconstructions especially when the reentry zone distally to an obstruction was located nearly an arterial bifurcation. 21 We straightened the concept of hypogastric salvage for several concepts. First, hypogastric salvage may be necessary in extensive aortic coverage especially in aortic reinterventions and during inferior mesenteric artery coverage for bowel ischemia prevention.…”
Section: Discussionmentioning
confidence: 99%
“…J o u r n a l P r e -p r o o f Background Double barrel stenting has been described in many contexts such as the management of cerebral artery aneurysms. [1][2][3] Additionally, the double barrel stenting technique has been used to preserve external and internal iliac artery flow, particularly in cases of dissection 4 or aneurysm 5 . Doublebarrel stenting involves the parallel deployment of stents with a similar origin but different outflow target.…”
mentioning
confidence: 99%
“… 1 , 2 , 3 Additionally, the double-barrel stenting technique has been used to preserve external and internal iliac artery flow, especially in cases of dissection or aneurysms. 4 , 5 Double-barrel stenting involves the parallel deployment of stents with a similar origin but different outflow targets. Although multiple reports have demonstrated the use of the technique, to the best of our knowledge, no studies have reported double-barrel stent repair of visceral artery dissecting aneurysms.…”
mentioning
confidence: 99%