2021
DOI: 10.1016/j.jcmg.2021.04.023
|View full text |Cite
|
Sign up to set email alerts
|

Hypoattenuated Leaflet Thickening After Transcatheter Pulmonary Valve Replacement With the SAPIEN 3 Valve

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 5 publications
1
3
0
Order By: Relevance
“…Subclinical leaflet thrombosis on CT is associated with increased gradients and adverse clinical events following transcatheter aortic valve replacement. This hypoattenuating leaflet thickening has been reported in post-TPVR patients with early valve failure 123,124 .…”
Section: Balloon-expandable Valvesupporting
confidence: 63%
“…Subclinical leaflet thrombosis on CT is associated with increased gradients and adverse clinical events following transcatheter aortic valve replacement. This hypoattenuating leaflet thickening has been reported in post-TPVR patients with early valve failure 123,124 .…”
Section: Balloon-expandable Valvesupporting
confidence: 63%
“…Effective valve orifice has not been correlated with degree of stenosis. Valve thickening, hypoattenuated leaflet thickening (HALT), 33 vegetation, thrombus, and calcification can be visualized and may help to determine the etiology of valve dysfunction and help guide appropriate treatment. 34 ( Figure 1 ).…”
Section: Multimodality Definitions Of Pulmonary Valve Bioprosthetic V...mentioning
confidence: 99%
“…Hypoattenuated leaflet thickening can be the cause of early valve gradient when associated with restricted leaflet motion, which can respond to anticoagulation obviating the need for valve replacement. 33 Endocarditis or thrombus can result in RVOT obstruction or new valvular regurgitation, and vegetations can be difficult to visualize by transthoracic or transesophageal echocardiography. Calcified or noncalcified valve leaflet thickening due to bioprosthetic valve degeneration may also cause obstruction and would not be amenable to medical therapies.…”
Section: Standardized Approach For Assessing and Reporting The Dysfun...mentioning
confidence: 99%
“…The ideal anticoagulation strategy postimplant remains unknown, with significant practice variation present among interventional cardiologists. [34][35][36]…”
Section: Q17mentioning
confidence: 99%