2015
DOI: 10.1039/c4ay02218a
|View full text |Cite
|
Sign up to set email alerts
|

Hyphenation of single-drop microextraction with laser-induced breakdown spectrometry for trace analysis in liquid samples: a viability study

Abstract: 15In this work, an analytical methodology based on Single Drop Microextraction (SDME) 16 followed by Laser-Induced Breakdown Spectrometry (LIBS) has been tested for trace metals 17 determination in liquid samples. By this method, analytes in the samples were extracted into a 18 small volume of toluene as ammonium pyrroldinedithiocarbamate (APDC) chelates. After 19 that, the analyte-enriched toluene was dried on a solid substrate and, finally, the resulting 20 solid residue was analyzed by LIBS. Analyte extr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 26 publications
(23 citation statements)
references
References 31 publications
0
23
0
Order By: Relevance
“…To the best of our knowledge, especially for Cd and Pb, this is the only study that sub-ppm detection limits are obtained from the direct analysis of liquids. When the literature results that incorporate enrichment strategies followed by the use of aluminum substrate [34][35][36] are compared, the present results are still at least an order of magnitude lower. Enhancement factors of 9 and 21 for Cu, and 7 and 45 for Mn were observed with respect to DLLE and SDME approaches.…”
Section: Growth Curves and Analytical Figures Of Meritmentioning
confidence: 68%
See 4 more Smart Citations
“…To the best of our knowledge, especially for Cd and Pb, this is the only study that sub-ppm detection limits are obtained from the direct analysis of liquids. When the literature results that incorporate enrichment strategies followed by the use of aluminum substrate [34][35][36] are compared, the present results are still at least an order of magnitude lower. Enhancement factors of 9 and 21 for Cu, and 7 and 45 for Mn were observed with respect to DLLE and SDME approaches.…”
Section: Growth Curves and Analytical Figures Of Meritmentioning
confidence: 68%
“…3(e), surface explosion with debris around the edges of the crater and contamination of the craters from the subsequent laser pulses are clearly observed. Instead of making several samplings with tightly focussed laser beam at different locations of a single droplet, as is shown in the literature by Aguirre et al in their several work [34][35][36], sampling the whole droplet area in a single laser shot may eliminates shot to shot variation of the signal due to inhomogeneous deposition of the analyte. In addition, sample losses between the samplings may also be prevented.…”
Section: Morphology Of the Cratersmentioning
confidence: 99%
See 3 more Smart Citations