2014
DOI: 10.1002/rcm.7056
|View full text |Cite
|
Sign up to set email alerts
|

Hyphenation of capillary high‐performance ion‐exchange chromatography with mass spectrometry using sheath‐flow electrospray ionization

Abstract: RATIONALE: Mass spectrometry (MS) is an attractive method for extending capillary-size ion chromatography (cHPIC) to create a valuable technique for speciation analysis. For hyphenation, the aqueous effluent of cHPIC has to be transformed into a volatile mixture for MS while preserving analytical concentrations as well as peak shapes during transfer from cHPIC to MS. Finally, the approach should technically be flexible and easy-to-use. A combination of cHPIC and sheath-flow electrospray ionization (ESI)-MS off… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(12 citation statements)
references
References 34 publications
0
12
0
Order By: Relevance
“…Secondly, their compatibility with traditional organic solvents used for sample extraction is limited, since most sampling protocols involve the use of organic solvents to ensure recovery of both the inorganic and organic compounds. Usually, these two problems are addressed by infusing organic solvents in the eluate using an auxiliary pump prior to ESI and solvent exchange with water before injection [26,27]. The full procedure is nonetheless lengthy and complicated, and often results in sub-optimal sensitivity.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Secondly, their compatibility with traditional organic solvents used for sample extraction is limited, since most sampling protocols involve the use of organic solvents to ensure recovery of both the inorganic and organic compounds. Usually, these two problems are addressed by infusing organic solvents in the eluate using an auxiliary pump prior to ESI and solvent exchange with water before injection [26,27]. The full procedure is nonetheless lengthy and complicated, and often results in sub-optimal sensitivity.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…129 Applying a 0.32 Â 100 mm column packed with 3 mm octadecyl silica (ODS) microparticles coated with hexadecyltrimethylammonium bromide and mixed eluent containing 1 mM sodium salicylate with 5% acetonitrile, Takeuchi's group developed another CIC method for inorganic anions. [135][136][137][138][139] Using an injection valve to couple CIC and MS was found to be the best method for hyphenation, since it constituted a exible and dead-volume-free approach. The BSA molecule, immobilized on 5 mm ODS particles, was protonated at specic pH condition and affected the anionic analyte retention.…”
Section: Cic Techniquementioning
confidence: 99%
“…130 Stationary phases coated with immobilized biological macromolecules, such as bovine serum albumin (BSA), has been introduced to the CIC technique innovation. 139 Fluorescence detection can be easily hyphenated with CIC as well. Using 0.35 Â 75-150 mm columns and an eluent containing NaI and tartaric acid, this method was successfully applied for indirect photometric detection of nitrite and bromide in tap water.…”
Section: Cic Techniquementioning
confidence: 99%
See 2 more Smart Citations