B63. Imaging: Evolving Technologies and Relation to Pathology 2009
DOI: 10.1164/ajrccm-conference.2009.179.1_meetingabstracts.a3546
|View full text |Cite
|
Sign up to set email alerts
|

Hyperpolarized Noble Gas Magnetic Resonance Imaging of a Gastric Aspiration Model of Acute Lung Injury in the Rat Lung.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
1
0

Year Published

2012
2012
2012
2012

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…2 Furthermore, HNGs can provide quantitative anatomical and functional information within the lungs of ventilated rodents such as ventilation and ventilated volume, perfusion, apparent diffusion coefficients (ADCs) and diffusing capacity, 3 including rodent models of emphysema, 4 asthma 5 as well as lung injury due to bleomycin, 6 radiation-induced lung injury 7 and gastric aspiration. 8 Typically, special MRI-compatible ventilators are used in conjunction with intubation to ensure consistent and timely HNG breath-holds in rodents; however, this limits the method to endpoint studies requiring larger numbers of animals due to the need for surgery to ensure an airtight seal between the endotracheal (ET) tube and the trachea. An airtight seal prevents the interaction of molecular oxygen with the HNGs which would otherwise destroy the observable MRI signal due to T 1 relaxation.…”
mentioning
confidence: 99%
“…2 Furthermore, HNGs can provide quantitative anatomical and functional information within the lungs of ventilated rodents such as ventilation and ventilated volume, perfusion, apparent diffusion coefficients (ADCs) and diffusing capacity, 3 including rodent models of emphysema, 4 asthma 5 as well as lung injury due to bleomycin, 6 radiation-induced lung injury 7 and gastric aspiration. 8 Typically, special MRI-compatible ventilators are used in conjunction with intubation to ensure consistent and timely HNG breath-holds in rodents; however, this limits the method to endpoint studies requiring larger numbers of animals due to the need for surgery to ensure an airtight seal between the endotracheal (ET) tube and the trachea. An airtight seal prevents the interaction of molecular oxygen with the HNGs which would otherwise destroy the observable MRI signal due to T 1 relaxation.…”
mentioning
confidence: 99%