2006
DOI: 10.1016/j.ab.2006.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Hydrophilic interaction liquid chromatography–electrospray ionization mass spectrometry of tetrodotoxin and its analogs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
44
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
4
3

Relationship

3
4

Authors

Journals

citations
Cited by 67 publications
(46 citation statements)
references
References 8 publications
2
44
0
Order By: Relevance
“…Further, toxin profiles from different species were studied by using HILIC-ESI-MS alone or in combination with other methods. The Yotsu-Yamashita group was able to discover not only the distribution of tetrodotoxin, saxitoxin, and their analogs [142,143], but also the presence of a new dideoxy analog of tetrodotoxin [144] from puffer fish using only HILIC-ESI-MS. Similarly, Dell'Aversano et al [145] analyzed the assorted toxins produced by cyanobacteria.…”
Section: Environmental Analysismentioning
confidence: 99%
“…Further, toxin profiles from different species were studied by using HILIC-ESI-MS alone or in combination with other methods. The Yotsu-Yamashita group was able to discover not only the distribution of tetrodotoxin, saxitoxin, and their analogs [142,143], but also the presence of a new dideoxy analog of tetrodotoxin [144] from puffer fish using only HILIC-ESI-MS. Similarly, Dell'Aversano et al [145] analyzed the assorted toxins produced by cyanobacteria.…”
Section: Environmental Analysismentioning
confidence: 99%
“…The lower limits of detection (signal-to-noise ratio = 3) with our instrument were 64 pg on-column for TTX, 128 pg for both 4-epiTTX and 4,9-anhydroTTX, and 180 pg for 5,6,11-trideoxyTTX. We previously reported that the lower limit of detection of TTX by LC-MS in the selected ion monitoring (SIM) mode was 192 pg on-column [11] using the same instrument as used in the present study. Optimization of detection conditions for MRM in the present study enhanced the sensitivity for TTX three times higher than that obtained by SIM of single-stage MS, but the sensitivity for 5,6,11-trideoxyTTX was almost the same as that by SIM.…”
Section: Resultsmentioning
confidence: 98%
“…TTXs were separated by HILC as reported previously [11,13,16]. Briefly, the LC system consisted of an LC-10AD pump (Shimadzu, Kyoto, Japan), a TSKgel Amide-80 column (150 9 2.0 mm i.d., particle size 5 lm, Tosoh, Tokyo, Japan), a vacuum degasser, and a Shimadzu SIL-HTA autosampler.…”
Section: Lc-ms-ms Conditionsmentioning
confidence: 99%
See 2 more Smart Citations