2020
DOI: 10.2174/1573412916666200316124837
|View full text |Cite
|
Sign up to set email alerts
|

Hydrophilic Interaction Chromatography Analysis of Esculin in Ointments with UV Detection

Abstract: Background: Esculin (ESCN) is used in the pharmaceutical industry with intravenous effect, stimulant and anti-inflammatory capillaries, like vitamin P. It is a significant component of many anti-inflammatory remedies such as esqusan, esflazid and anavenol [14]. It is also found in numerous other remedies available in the market such as proctosone, anustat, and ariproct. Objective: To determine experimental conditions, to elucidate retention behavior of esculin in HILIC mode. Moreover, to suggest new ways to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 24 publications
0
3
0
Order By: Relevance
“…The mobile phase was filtered with 0.45 µm filters. The first-dimension column utilized a home-made ZIC-HILIC column, ZIC-SB5 (100 mm x 4.6 mm) 47 Ȧ, particle size 3.5 µm, following the reference [38][39][40]. while the second-dimension column was obtained from Nouryon-Kromasil (Sweden), RP column, Kromasil C18 (50 mm x 3.0 mm id) 100 Ȧ, particle size 5µm.…”
Section: Methodsmentioning
confidence: 99%
“…The mobile phase was filtered with 0.45 µm filters. The first-dimension column utilized a home-made ZIC-HILIC column, ZIC-SB5 (100 mm x 4.6 mm) 47 Ȧ, particle size 3.5 µm, following the reference [38][39][40]. while the second-dimension column was obtained from Nouryon-Kromasil (Sweden), RP column, Kromasil C18 (50 mm x 3.0 mm id) 100 Ȧ, particle size 5µm.…”
Section: Methodsmentioning
confidence: 99%
“…Additionally, the influence of the chain longitude of the ZIC-HILIC columns on ketoprofen retention behaviour has not been examined previously. Rasheed and colleagues [19,27] have investigated the influence of chain length on HILIC columns and its effect on the Ranitidine and esculin behaviour. They discovered that the longer the chain length, the more interaction between the Ranitidine and esculin and the ZIC-HILIC column occurs, resulting in a longer retention time.…”
Section: Introductionmentioning
confidence: 99%
“…Rasheed and his team have presented numerous studies employing the HILIC technique in various applications, and are mentioned in the following references. [11][12][13][14][15][16][17][18][19][20][21]…”
mentioning
confidence: 99%