2007
DOI: 10.1562/0031-8655(2000)0720392hcdaca2.0.co2
|View full text |Cite
|
Sign up to set email alerts
|

Hydrophilic Cyanine Dyes as Contrast Agents for Near-infrared Tumor Imaging: Synthesis, Photophysical Properties and Spectroscopic In vivo Characterization ¶

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
55
0
1

Year Published

2007
2007
2024
2024

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 60 publications
(58 citation statements)
references
References 32 publications
2
55
0
1
Order By: Relevance
“…The amphiphilic character of ICG induces aggregation in aqueous solution resulting in adverse effects on its optical properties, such as lower quantum yields due to self quenching (17,18). Also, tumor localization is limited to a rather short period of time after administration due to the strong plasma protein binding of ICG and subsequent rapid clearance by the liver (19). Furthermore, ICG undergoes degradation in aqueous media, resulting in a loss of absorption and fluorescence due to saturation of the double bonds in the conjugated chain (20).…”
Section: Introductionmentioning
confidence: 99%
“…The amphiphilic character of ICG induces aggregation in aqueous solution resulting in adverse effects on its optical properties, such as lower quantum yields due to self quenching (17,18). Also, tumor localization is limited to a rather short period of time after administration due to the strong plasma protein binding of ICG and subsequent rapid clearance by the liver (19). Furthermore, ICG undergoes degradation in aqueous media, resulting in a loss of absorption and fluorescence due to saturation of the double bonds in the conjugated chain (20).…”
Section: Introductionmentioning
confidence: 99%
“…In relation to interactions derived from the chromophore, plasma-binding properties of cyanines, in general, and their hydrophilic substitutes have already been observed. 25 The influence of other methodological effects on the aforementioned relationships should be rather minimal. For example, both tumor models have been implanted subcutaneously and had comparable sizes (approximately, 0.5 cm in diameter), so that light penetration depth was rather comparable between each other (depth variation was estimated to be lower than 0.3 mm).…”
Section: Discussionmentioning
confidence: 99%
“…This home built imaging system was reported in our previous work [12,13]. Briefly, the NIR system is composed of an excitation laser (λ=765.9 nm, NL-FC-2.0-763 laser light), a high sensitivity NIR CCD camera (PIXIS 512B, Princeton Instrumentation) and a 800 nm long pass filter for capturing the fluorescence from the tissue.…”
Section: Reagentsmentioning
confidence: 99%