2019
DOI: 10.1016/j.ijhydene.2019.03.013
|View full text |Cite
|
Sign up to set email alerts
|

Hydrogen isotopic effect during the graphite high-temperature corrosion in water vapours

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 13 publications
0
2
0
1
Order By: Relevance
“…The lack of objective data on the processes of corrosion and degradation in corrosive media opens up broad prospects for researchers to conduct such experiments. Interest in them is due to the possibility of obtaining kinetic curves of the degradation rate, which in the future will make it possible to contribute to the characterization of lithium-containing ceramics for thermonuclear power engineering [21][22][23][24][25]. Also of particular interest is the study of the effect of the presence of two-phase structures on resistance to degradation, since earlier studies indicate that two-phase ceramics have higher strength and durability [25][26][27].…”
Section: Introductionmentioning
confidence: 99%
“…The lack of objective data on the processes of corrosion and degradation in corrosive media opens up broad prospects for researchers to conduct such experiments. Interest in them is due to the possibility of obtaining kinetic curves of the degradation rate, which in the future will make it possible to contribute to the characterization of lithium-containing ceramics for thermonuclear power engineering [21][22][23][24][25]. Also of particular interest is the study of the effect of the presence of two-phase structures on resistance to degradation, since earlier studies indicate that two-phase ceramics have higher strength and durability [25][26][27].…”
Section: Introductionmentioning
confidence: 99%
“…Study of thermophysical properties of tin-lithium alloys of various composition were carried out on the TiGrA experimental complex [16,17] under the following conditions: Temperature range of sample heating: from 150 о С to 300 о С; Rate of linear heating of the sample: 10 о С/min; Gas medium composition in the chamber -air. Figure 2 shows a general view of the TiGrA complex.…”
Section: Experimental Technique and Research Conditionsmentioning
confidence: 99%
“…образцов оловянно-литиевой эвтектики различного состава [11][12][13][14]. Также исследовалась высокотемпературная коррозия графита марки IG-110, используемого в реакторных установках [15].…”
Section: Introductionunclassified