2012
DOI: 10.2214/ajr.11.7384
|View full text |Cite
|
Sign up to set email alerts
|

Hydrogen-1 MR Spectroscopy for Measurement and Diagnosis of Hepatic Steatosis

Abstract: OBJECTIVE Hydrogen-1 MR spectroscopy (1H-MRS) is gaining acceptance as a noninvasive technique for assessment of hepatic steatosis, and the findings have been found to correlate closely with histopathologic grade. The aims of this study were to validate 1H-MRS performed with a 3-T MRI system for quantifying hepatic steatosis and to determine threshold values of 1H-MRS proton density fat fraction corresponding to standard histopathologic grade in patients undergoing diagnostic liver biopsy. SUBJECTS AND METHO… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
37
0
2

Year Published

2014
2014
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(39 citation statements)
references
References 30 publications
0
37
0
2
Order By: Relevance
“…With regard to reproducibility, Bland-Altman analysis of scans repeated using our technique shows a mean difference between same-day scans of 0.29% (95% CI: −1.46 and 2.05%) 14 . The diagnostic accuracy of MRS for liver steatosis is high with an area under the receiver operating characteristic curve of 0.94 (95% CI 0.88–1.0) compared to assessment of liver biopsy by an experienced pathologist 17 . For measurement of VAT and SAT, single-slice CT has an estimated correlation between repeat measurements of 0.99, with errors in precision estimated at 1.9% for SAT and 3.9% for VAT 18 .…”
Section: Methodsmentioning
confidence: 96%
“…With regard to reproducibility, Bland-Altman analysis of scans repeated using our technique shows a mean difference between same-day scans of 0.29% (95% CI: −1.46 and 2.05%) 14 . The diagnostic accuracy of MRS for liver steatosis is high with an area under the receiver operating characteristic curve of 0.94 (95% CI 0.88–1.0) compared to assessment of liver biopsy by an experienced pathologist 17 . For measurement of VAT and SAT, single-slice CT has an estimated correlation between repeat measurements of 0.99, with errors in precision estimated at 1.9% for SAT and 3.9% for VAT 18 .…”
Section: Methodsmentioning
confidence: 96%
“…58 IHCL content measured with MRS in adults has been shown to have good diagnostic accuracy and compares favourably with the gold standard of liver biopsy for the quantitative measurement of hepatic steatosis. 59 SMOFlipid has been shown to be liver protective in the context of intestinal failure and PN in children and adults. Increasingly, the use of SMOFlipid has been adopted for use in neonates with liver impairment.…”
Section: Resultsmentioning
confidence: 99%
“…Ayrıca bu çalışma göstermiştir ki, US ile MR arasındaki bu uyum yağlanma yokluğunda da yüksektir. Bizim çalışmamızda MRG sinyal şiddeti ile ölçülen doku yağ oranı için kullandığımız eşik değer %5.1 olup değişik çalışmalarda %5, %5.1, %5.56, %8, %17 gibi farklı eşik değerler biyopsi ve MRS ile karşılaştırılmış ve iyi korelasyon göstermiştir [9,13,18,19]. Yine de yağlanmanın MR derecesi ile US derecesi arasında birebir denklik olmaması beklenti dahilindedir.…”
Section: Discussionunclassified