Hydrodynamics of the Certas™ programmable valve for the treatment of hydrocephalus

Abstract: BackgroundThe new Certas™ shunt for the treatment of hydrocephalus has seven standard pressure settings that according to the manufacturer range from 36 to 238 mmH2O, and an additional “Virtual Off” setting with an opening pressure >400 mmH2O. Information on actual pressure response and reliability of shunt performance is important in clinical application, especially the “Virtual Off” setting as a non-surgical replacement for shunt ligation. The objective of this study was to evaluate the in-vitro hydrodynamic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 23 publications
0
10
0
Order By: Relevance
“…Another hypothesis is that CSF dynamics may require longer times (> 24 h) to adapt to a new valve setting. The hydrodynamics of valve setting adjustments have been investigated in several in vitro studies [1,6,8,10]. Information on the effect of valve setting adjustments on ICP in vivo is scarce.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Another hypothesis is that CSF dynamics may require longer times (> 24 h) to adapt to a new valve setting. The hydrodynamics of valve setting adjustments have been investigated in several in vitro studies [1,6,8,10]. Information on the effect of valve setting adjustments on ICP in vivo is scarce.…”
Section: Discussionmentioning
confidence: 99%
“…The hydrodynamics of valve setting adjustments have been investigated in several in vitro studies [ 1 , 6 , 8 , 10 ]. Information on the effect of valve setting adjustments on ICP in vivo is scarce.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Opening pressures for different shunt models were transformed to mm H 2 O for conformity. 3,9 At one of the centers, a retrospective post hoc analysis on all patients undergoing surgical treatment for their SDH was performed by a senior consultant scrutinizing the patient files and CT/MR images of the brain. The combined information from these files and investigations was evaluated for symptoms and signs and classified as surgery needed or not needed.…”
Section: Registry Data and Validationmentioning
confidence: 99%
“…This was connected to a pediatric Codman Certas valve (DePuy Codman, Raynham, MA), which was set to 3 (approximately 8 mmHg). [ 5 ] The distal catheter was placed in the peritoneal cavity. A contralateral Ommaya reservoir was then placed into the frontal horn of the left lateral ventricle.…”
Section: Case Reportmentioning
confidence: 99%