2018
DOI: 10.1016/j.seppur.2018.04.039
|View full text |Cite
|
Sign up to set email alerts
|

Hydrodynamic study of three-phase flow in column flotation using electrical resistance tomography coupled with pressure transducers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

4
12
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(16 citation statements)
references
References 70 publications
4
12
0
Order By: Relevance
“…The air flowrate was maintained within the range of 0.6-1.8 cm/s superficial velocities (J g ). Previously, the analysis of hydrophilic silica slurry experiments based on DOE of fractional factorials for column flotation was published elsewhere by authors [24]. As the present study aims to compare gas hold-up changes at different solid concentrations for two different mineral particles, some of the specific silica slurry experiments have been conducted similar to coal slurry experiments.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The air flowrate was maintained within the range of 0.6-1.8 cm/s superficial velocities (J g ). Previously, the analysis of hydrophilic silica slurry experiments based on DOE of fractional factorials for column flotation was published elsewhere by authors [24]. As the present study aims to compare gas hold-up changes at different solid concentrations for two different mineral particles, some of the specific silica slurry experiments have been conducted similar to coal slurry experiments.…”
Section: Methodsmentioning
confidence: 99%
“…ERT has been utilized for bubble columns by Vakamalla et al [22] for estimating the bubble dynamics thereby measuring the mixing time successfully. Recently, authors have investigated to characterize the column flotation hydrodynamics using the ERT for both air-water and slurry systems (Vadlakonda and Mangadoddy [23,24]) and validated the measured phase holdup with respect to the other conventional approaches. Slurry system was considered to be consisting of hydrophobic silica particles.…”
Section: Introductionmentioning
confidence: 99%
“…Operating system was initiated by inducing electrical current between one pair of electrodes and differential potentials for all remaining pairs are measured (can be seen clearly in Fig. 1) [18]. The functions of DAS are to collect the real-time instantaneous signals output from sensing electrode arrays and to reflect the measured field to 2D or 3D distribution [19].…”
Section: Methodsmentioning
confidence: 99%
“…However, to our knowledge, no data have been published on the interaction between different reagents involved in the fluorite flotation process. Some authors have used the technique of design of experiments (DoE) to optimize some chemical and physical variables of flotation process, for example [22] use this technique to optimize the dosage of collector in the flotation of apatite and [23] Use DoE to study some hydrodynamic aspects in column flotation.…”
Section: Introductionmentioning
confidence: 99%