2019
DOI: 10.1016/j.sab.2019.05.019
|View full text |Cite
|
Sign up to set email alerts
|

Hydride generation atomic absorption spectrometry with a dielectric barrier discharge atomizer: Method optimization and evaluation of analytical performance for tin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 22 publications
0
8
0
Order By: Relevance
“…Externally heated quartz tube atomizers (QTA) including their advanced designs, such as multiple microflame quartz tube atomizer (MMQTA), are the most common hydride atomizers in AAS characterized by high sensitivity 2,[15][16][17] . Addition of air or oxygen to MMQTA through the outer (auxiliary) gas channel increases sensitivity in case of As, 18,19 Sn, 20,21 Se, 18,22,23 and Te 23 determination benefiting thus from MMQTA construction. The sensitivity reached in QTA/MMQTA is quite comparable among seven hydride forming elements including As, Se, Sb, Bi, Te, Pb and Sn.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Externally heated quartz tube atomizers (QTA) including their advanced designs, such as multiple microflame quartz tube atomizer (MMQTA), are the most common hydride atomizers in AAS characterized by high sensitivity 2,[15][16][17] . Addition of air or oxygen to MMQTA through the outer (auxiliary) gas channel increases sensitivity in case of As, 18,19 Sn, 20,21 Se, 18,22,23 and Te 23 determination benefiting thus from MMQTA construction. The sensitivity reached in QTA/MMQTA is quite comparable among seven hydride forming elements including As, Se, Sb, Bi, Te, Pb and Sn.…”
Section: Introductionmentioning
confidence: 99%
“…It is comparable with the sensitivity reached in QTA/MMQTA for some analytes such as As, 19 Se, 22,23 Sb, 28 and Te 23, 29 while being significantly lower in DBD for the others including Bi 23, 30 and especially Pb 23,31 and Sn. 20 Apart from QTA and DBD atomizers the hydride forming elements can also be atomized in the atomizers based on diffusion flame (DF) or graphite tube (GT). 2,15 DF is commonly used in AFS rather than AAS since its short optical path is responsible for low sensitivity in AAS leading to 50 times lower signals when compared to QTA or MMQTA.…”
Section: Introductionmentioning
confidence: 99%
“…With an LOD of 12 pg mL −1 , this compared reasonably well with other trapping methods. In a third paper, 44 the same research group optimised the system for trapping Sn.…”
Section: Sample Introductionmentioning
confidence: 99%
“…Moreover, some heavy metals (As, for instance) has been classified as mutagenic and carcinogenic leading to serious diseases 15 . For these reasons, several techniques have been continually developed for the determination of heavy metals such as atomic absorption spectrometry (AAS) 16,17 , inductively coupled plasma optical emission spectrometry (ICP-OES) 18 , and inductively coupled plasma mass spectrometry (ICP-MS) 19 . However, limitations such as their bulky instruments, high-cost and non-portability are a bottleneck which still requires a major development presuming that it will be further used for on-field analysis.…”
mentioning
confidence: 99%
“…17 Comparison of the performance of the proposed method using gPADs with a conventional UV-VIS spectrophotometric method in air samples (n=3)…”
mentioning