2010
DOI: 10.1073/pnas.0915163107
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid PET-optical imaging using targeted probes

Abstract: Fusion imaging of radionuclide-based molecular (PET) and structural data [x-ray computed tomography (CT)] has been firmly established. Here we show that optical measurements [fluorescence-mediated tomography (FMT)] show exquisite congruence to radionuclide measurements and that information can be seamlessly integrated and visualized. Using biocompatible nanoparticles as a generic platform (containing a 18 F isotope and a far red fluorochrome), we show good correlations between FMT and PET in probe concentratio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
186
0
1

Year Published

2011
2011
2019
2019

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 205 publications
(190 citation statements)
references
References 36 publications
3
186
0
1
Order By: Relevance
“…Its applications include real-time, intraoperative detection and imaging of nodal metastases, differential tumor burden, and lymphatic drainage patterns in melanoma. Although several investigators have synthesized radiolabeled fluorescent particle probes (25,30,40), our multimodal agent has been radiolabeled with the long-lived positron-emitter iodine-124, and, thus, we believe it can provide unique longer-term pharmacokinetic clearance and targeting information over the course of days. The complementary nature of this platform, coupled with its small size (~7-nm i.d.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Its applications include real-time, intraoperative detection and imaging of nodal metastases, differential tumor burden, and lymphatic drainage patterns in melanoma. Although several investigators have synthesized radiolabeled fluorescent particle probes (25,30,40), our multimodal agent has been radiolabeled with the long-lived positron-emitter iodine-124, and, thus, we believe it can provide unique longer-term pharmacokinetic clearance and targeting information over the course of days. The complementary nature of this platform, coupled with its small size (~7-nm i.d.…”
Section: Discussionmentioning
confidence: 99%
“…Bifunctional PEGs, MALdPEG12-NHS ester (Quanta Biodesigns Ltd.), were derivatized with silanes, specifically 3-aminopropyl triethoxysilane (Gelest), for attachment to the silica surface and for peptide coupling via reactions between the sulfhydryl groups and maleimide moieties of the derivatized PEGs. In addition, methoxy-capped PEG chains were added to the particle surface using functional organosilicon compounds (Si compounds), specifically (MeO)3Si-PEG (Gelest), according to modified protocols (40). Briefly, (MeO)3Si-PEG was added, at approximately 3 molar excess, to particles in a water/alcohol basic mixture (~1:5 v/v), and the mixture was stirred overnight at room temperature.…”
Section: Synthesis Of Crgdy-peg-dots Crady-peg-dots and Peg-dotsmentioning
confidence: 99%
“…Extending several pioneering efforts with regard to the combination of FMT with microcomputed tomography (μCT) for molecular imaging purposes, [31][32][33] using HPMA-based and NIRF-labeled polymeric nanocarriers known to accumulate in tumors both effectively and selectively by means of EPR, 10,12,34,35 we here show that hybrid CT-FMT imaging can be employed to non-invasively assess the accumulation of nanomedicine formulations in tissues other than superficial / subcutaneous tumors. To this end, the biodistribution and tumor accumulation of 5-10 nm-sized Dy750-labeled polymeric carrier materials was visualized and quantified using 3D FMT, and the data sets obtained were fused with 3D anatomical μCT data sets in which several different physiologically relevant organs were pre-segmented.…”
mentioning
confidence: 99%
“…12 The nanoparticle had a cross-linked iron oxide core with a dextran surface with a blood half-life of about 6 h and excretion of less than 5% at 24 h (Figure 4(A)). A specially designed imaging cassette was used for PET/CT/optical imaging (Figure 4(B)).…”
Section: F (mentioning
confidence: 99%