2011
DOI: 10.1021/ct200132n
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid Particle-Field Coarse-Grained Models for Biological Phospholipids

Abstract: In the framework of a recently developed scheme for a hybrid particle-field simulation technique where self-consistent field theory (SCF) and molecular dynamics (MD) are combined [ J. Chem. Phys. 2009 , 130 , 214106 ], specific coarse-grained models for phospholipids and water have been developed. We optimized the model parameters, which are necessary in evaluating the interactions between the particles and the density fields, so that the coarse-grained model can reproduce the structural properties of the refe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
159
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
1

Relationship

5
2

Authors

Journals

citations
Cited by 70 publications
(168 citation statements)
references
References 53 publications
(84 reference statements)
2
159
0
Order By: Relevance
“…The coarse-grained models adopted in this study for lipids have been extensively described and validated in two previous papers [39,40] and recently reviewed in the framework of efficient strategies for biomembranes modelling [33]. The main advantage of hybrid MD-SCF scheme is that the most computationally expensive part of the MD simulations, i.e.…”
Section: Simulation Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…The coarse-grained models adopted in this study for lipids have been extensively described and validated in two previous papers [39,40] and recently reviewed in the framework of efficient strategies for biomembranes modelling [33]. The main advantage of hybrid MD-SCF scheme is that the most computationally expensive part of the MD simulations, i.e.…”
Section: Simulation Methodologymentioning
confidence: 99%
“…The calculations of the fields have been performed using a grid with a resolution of 0.705 nm and an update frequency of 300 steps. This choice of the grid size guarantees good reproduction of lipid properties [39,40]. Furthermore the value 0.705 nm is almost half of the CNTs diameters, in this way excluded volume interactions between CNTs is properly described by the incompressibility condition (second addend of eq.…”
Section: Simulation Detailsmentioning
confidence: 98%
“…in which the projection algorithm is called every tenth time step, was considered in the original MD-SCF model, and even larger values were found suited in specific cases. 29 This value is determined by the optimum between efficiency and both the effective particle dynamics and field resolution, in particular how fast the density fields at the chosen resolution changes given the underlying particle dynamics. The value f up = 10 was considered a conservative choice, 29 and we will use it as the initial value.…”
Section: Practical Implementation Of Md-scf/mpcd For a Lipid Modelmentioning
confidence: 99%
“…29 This value is determined by the optimum between efficiency and both the effective particle dynamics and field resolution, in particular how fast the density fields at the chosen resolution changes given the underlying particle dynamics. The value f up = 10 was considered a conservative choice, 29 and we will use it as the initial value. Nevertheless, later on, we discuss the need for using smaller values.…”
Section: Practical Implementation Of Md-scf/mpcd For a Lipid Modelmentioning
confidence: 99%
See 1 more Smart Citation