2014
DOI: 10.1109/jlt.2014.2308060
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid Miniature Fabry–Perot Sensor with Dual Optical Cavities for Simultaneous Pressure and Temperature Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
56
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 101 publications
(57 citation statements)
references
References 30 publications
1
56
0
Order By: Relevance
“…With this selection, 20 sensors can be packed in an FPI array maintaining at least 10 dB selectivity between each peak (ρ = 0.175, η = 25 µm), or it is possible to expand the capacity up to 39 sensors (ρ = 0.0825, η = 15 µm) still maintaining at least 4 dB selectivity between each PSD peak, for SNR > 36 dB. These values are a great improvement over the 2-3 peaks detected so far with FFT [14][15], and lean towards closing the gap with FBG sensors, which operate typically with up to 20-80 sensors on the same 80 nm bandwidth used in FPI simulation. …”
Section: B Capacitymentioning
confidence: 94%
See 1 more Smart Citation
“…With this selection, 20 sensors can be packed in an FPI array maintaining at least 10 dB selectivity between each peak (ρ = 0.175, η = 25 µm), or it is possible to expand the capacity up to 39 sensors (ρ = 0.0825, η = 15 µm) still maintaining at least 4 dB selectivity between each PSD peak, for SNR > 36 dB. These values are a great improvement over the 2-3 peaks detected so far with FFT [14][15], and lean towards closing the gap with FBG sensors, which operate typically with up to 20-80 sensors on the same 80 nm bandwidth used in FPI simulation. …”
Section: B Capacitymentioning
confidence: 94%
“…FPI decoding methods based on Fast Fourier Transform (FFT) [14] have typically applied for single, dual, or triple [15] cavity detection. Recently, the work of Barrera, et al [16] reported the fabrication and interrogation of serial interferometers, with an FFT-based method validated for up to 4 sensors.…”
Section: Introductionmentioning
confidence: 99%
“…Various hybrid structured FPIs have been fabricated for concurrent measurement of temperature and pressure 12 , temperature and refractive index 13 , pressure and temperature 14, 15 , temperature and strain 16 . In 2012, Pevec S. et al .…”
Section: Introductionmentioning
confidence: 99%
“…Now the measurement principle of optical fiber temperature sensors include primarily wavelength shift of long-period fiber grating [1], coating with temperature-sensitive material on optical fiber surface [2], Fresnel reflection (temperature resolution 0.07°C) [3], Mach-Zehnder interferometer (temperature sensitivity 109 pm/°C) [4], Fabry-Perot interferometer (temperature sensitivity 2.9 nm/°C) [5]. Compared with the above sensors, FBG-based temperature sensors have been intensively studied due to its advantages such as high precision, simple structure, rapid response, etc [6]- [12].…”
Section: Introductionmentioning
confidence: 99%