Hybrid Islanding Detection in Microgrid With Multiple Connection Points to Smart Grids Using Fuzzy-Neural Network

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
61
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 103 publications
(62 citation statements)
references
References 20 publications
0
61
0
1
Order By: Relevance
“…Similarly, wavelet based ANFIS is also used in active ID technique through d axis signal injection for a UL 1741 test configuration [116]. A hybrid islanding technique using ANFIS is implemented in [117] based on probability of islanding (PoI) values on Smart grid side. Table 4 shows the comparison between various classifier IDMs.…”
Section: Anfismentioning
confidence: 99%
“…Similarly, wavelet based ANFIS is also used in active ID technique through d axis signal injection for a UL 1741 test configuration [116]. A hybrid islanding technique using ANFIS is implemented in [117] based on probability of islanding (PoI) values on Smart grid side. Table 4 shows the comparison between various classifier IDMs.…”
Section: Anfismentioning
confidence: 99%
“…The second system with multiple DGs consists of battery storage as DG and some parts including wind, a diesel generator, and local loads with a CB for studying various situations as observed in Figure 19. 26 In this test system, MG under consideration has two subsystems with one connection point to utility grid, and there are various loads such as main load and variable load. When an islanding occurs, the MG configuration is planned in such manner that the current and voltage will not be modified notably due to the presence of sub-MG supplying the local loads.…”
Section: System With Multiple Dgsmentioning
confidence: 99%
“…In addition, the proposed hybrid method is considered for a system with three DGs under the grid-connected and disconnected operational conditions according to UL1741Std. 2,[26][27][28] Different schemes of the active and reactive power under UL1547 are tested. The load parameters are shown in Table 2, and the related simulation results are depicted in Figure 22.…”
Section: System With Multiple Dgsmentioning
confidence: 99%
“…In a previous study, a hybrid IDT based on the combination of the slip mode frequency shift (an active IDT) and ROCOF and over/under frequency relay (a passive IDT) has been proposed. Another hybrid IDT based on the probability of islanding (PoI) which uses a combination of active active passive along with communication‐based technique (a remote IDT) is suggested in another study …”
Section: Introductionmentioning
confidence: 99%