2016
DOI: 10.1016/j.diamond.2016.03.016
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid gas sensor based on platinum nanoparticles/poly(methyl methacrylate)-coated single-walled carbon nanotubes for dichloromethane detection with a high response magnitude

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…31,32) For the GR=PMMA sensor, the main sensing mechanism can be described in terms of polymer swelling due to VOC adsorption and the Hansen solubility parameter (HSP) similarly to polymer-coated carbon nanotubes. 33,34) A hypothesis based on polymer swelling can be described as follows. After VOC adsorption, PMMA on graphene layer becomes swollen, resulting in an increase in electrical resistance due to the increase in polymer volume and graphene sheet bending.…”
Section: Sensing Mechanism Of Graphene and Gr/pmma Sensormentioning
confidence: 99%
“…31,32) For the GR=PMMA sensor, the main sensing mechanism can be described in terms of polymer swelling due to VOC adsorption and the Hansen solubility parameter (HSP) similarly to polymer-coated carbon nanotubes. 33,34) A hypothesis based on polymer swelling can be described as follows. After VOC adsorption, PMMA on graphene layer becomes swollen, resulting in an increase in electrical resistance due to the increase in polymer volume and graphene sheet bending.…”
Section: Sensing Mechanism Of Graphene and Gr/pmma Sensormentioning
confidence: 99%
“…Due to its high volatility, the inhalation reference exposure level is limited to 100 ppb or 400 μ g/m3 to prevent human workers from experiencing the key effects of carboxyhemoglobin (COHb) formation. In industry, [6][7]dcm is widely used as paint and varnish remover, aerosol as cosolvent or vapor pressure inhibitor, solvent degreasing and metal cleaning applications, plastic processing and extraction of fat and oil from food. Interestingly, it is also used to decaffeinate coffee and tea.…”
Section: Introductionmentioning
confidence: 99%
“… 22,23 Winadda et al proposed a DCM sensor based on carbon nanotubes that can be easily operated at room temperature but has a high detection limit. 28 In recent years, considerable advances have been achieved in optical or photoelectric DCM sensors due to the superiority of optical signals in fast response, low loss, and flexible optical spectra modulation. Han et al have introduced a DCM detector based on near-infrared absorptive sensing and obtained high resolution, 29 while the optical sensor based on fluorescence quenching behavior in Cd metal–organic framework is found to be highly efficient.…”
Section: Introductionmentioning