2007
DOI: 10.1016/j.bioelechem.2006.12.004
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid bioelectrocatalyst for hydrogen peroxide reduction: Immobilization of enzyme within organic–inorganic film of structured Prussian Blue and PEDOT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
12
0

Year Published

2009
2009
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 43 publications
(14 citation statements)
references
References 38 publications
2
12
0
Order By: Relevance
“…9A shows the chronoamperogram for electrochemical reduction of H 2 O 2 at PEDOT-PB composite coating prepared according to the preparation procedure described in the Table 3. Table 3 near here Table 3 shows that the analytical performances of the PEDOT-PB-soluble modified electrode are comparable with those reported in the literature [43][44][45][46][47]. Furthermore, the pure PEDOT-ClO 4 and the PEDOT-FeCN coatings showed no response to hydrogen peroxide reduction under the same experimental conditions, a behavior that demonstrates the usefulness of PEDOT-PB composite materials in hydrogen peroxide detection.…”
Section: Electrochemical Detection Of Hydrogen Peroxide At Pt/pedot-psupporting
confidence: 81%
“…9A shows the chronoamperogram for electrochemical reduction of H 2 O 2 at PEDOT-PB composite coating prepared according to the preparation procedure described in the Table 3. Table 3 near here Table 3 shows that the analytical performances of the PEDOT-PB-soluble modified electrode are comparable with those reported in the literature [43][44][45][46][47]. Furthermore, the pure PEDOT-ClO 4 and the PEDOT-FeCN coatings showed no response to hydrogen peroxide reduction under the same experimental conditions, a behavior that demonstrates the usefulness of PEDOT-PB composite materials in hydrogen peroxide detection.…”
Section: Electrochemical Detection Of Hydrogen Peroxide At Pt/pedot-psupporting
confidence: 81%
“…Among others, electrochromic and magnetic properties, their possible use as a biosensor or their electrocatalytic behavior are of special interest [1][2][3][4][5][6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…Figures 4-7 show that the concentrations of these compounds can affect the redox response of the resulting modified electrodes, which agrees with the mechanism of the formation of the second layer mentioned in the introduction part. [22][23][24][25][26] From these figures we can see that the optimum conditions are 0.4 M KCl, 1×10 −3 M CuCl 2 , 0.1 M K 3 Fe(CN) 6 and 0.4 M HCl.…”
Section: Factors Affecting the Electrochemical Preparation Of The Commentioning
confidence: 99%