2019
DOI: 10.1016/j.snb.2019.04.017
|View full text |Cite
|
Sign up to set email alerts
|

Humidity sensor based on unsymmetrical U-shaped twisted microfiber coupler with wide detection range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 27 publications
(11 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…The resulting tapered SMF coupler has been used for sensing applications, including temperature [226][227], RI [228][229][230], strain [231], liquid flow rate [232] and magnetic field sensing [233][234][235][236][237] etc. The functionalization of tapered SMF couplers enables the sensors to be used to detect bio-chemical materials, such as humidity [238][239], ammonia [240], ethanol [241], human cardiac troponin, in which the Vernier effect was utilized to improve sensor sensitivity [242], airborne contaminants [243], myocardial infarction I [244].…”
Section: B Tapered Sms Fiber Couplermentioning
confidence: 99%
“…The resulting tapered SMF coupler has been used for sensing applications, including temperature [226][227], RI [228][229][230], strain [231], liquid flow rate [232] and magnetic field sensing [233][234][235][236][237] etc. The functionalization of tapered SMF couplers enables the sensors to be used to detect bio-chemical materials, such as humidity [238][239], ammonia [240], ethanol [241], human cardiac troponin, in which the Vernier effect was utilized to improve sensor sensitivity [242], airborne contaminants [243], myocardial infarction I [244].…”
Section: B Tapered Sms Fiber Couplermentioning
confidence: 99%
“…This feature is caused by the larger evanescent fields in smaller dimensions or reduced RI contrast, indicating that microfiber sensors with smaller diameters would benefit sensing applications. To date, MFCs have been widely demonstrated in the sensing of RIs [96,100,182], temperature [72,75,183,184], strain/force [97], current [94], magnetic fields [94,176], humidity [169,185,186], and other parameters. Most of the reported MFC RI sensors exhibited sensitivities in the range of 1 000 nm/RIU -6 000 nm/RIU (RI unit) [93,95,96,187,188].…”
Section: Phase-based Sensorsmentioning
confidence: 99%
“…A polyvinyl alcohol (PVA) polymer was employed as an absorber of relative humidity to realize a MKR-based relative humidity sensor [29,30,48,49,50,51,52,53,54]. FM-MKR with two modes ( HE 11 and HE 12 ) was fabricated by using a flame-blushing method [29].…”
Section: Relative Humidity Sensors Based On Mkrs With Sensitive Mamentioning
confidence: 99%