1990
DOI: 10.1016/0020-7292(90)90667-a
|View full text |Cite
|
Sign up to set email alerts
|

Human papillomavirus DNA in CO2 laser‐generated plume of smoke and its consequences to the surgeon

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
94
0
8

Year Published

1998
1998
2021
2021

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 93 publications
(104 citation statements)
references
References 0 publications
2
94
0
8
Order By: Relevance
“…Furthermore, differing methods of capturing surgical smoke might also be an issue. An experiment by Ferenczy, Bergeron, and Richart (1990) to trap HPV DNA revealed no viable samples in surgical smoke, whereas other studies were able to do so. According to Ferenczy et al (1990), this might be due to the type of capture method used in the experiment.…”
Section: Issues In Research Designmentioning
confidence: 93%
See 2 more Smart Citations
“…Furthermore, differing methods of capturing surgical smoke might also be an issue. An experiment by Ferenczy, Bergeron, and Richart (1990) to trap HPV DNA revealed no viable samples in surgical smoke, whereas other studies were able to do so. According to Ferenczy et al (1990), this might be due to the type of capture method used in the experiment.…”
Section: Issues In Research Designmentioning
confidence: 93%
“…An experiment by Ferenczy, Bergeron, and Richart (1990) to trap HPV DNA revealed no viable samples in surgical smoke, whereas other studies were able to do so. According to Ferenczy et al (1990), this might be due to the type of capture method used in the experiment. Further to this point, Brandon and Young (1997) believed that point-oforigin suction might only clear 50% of surgical smoke because of suction blockage or ineffective orientation of the suction device, resulting in inaccurate capture and measurement of smoke exposure.…”
Section: Issues In Research Designmentioning
confidence: 93%
See 1 more Smart Citation
“…Despite most research suggesting that this is inadequate, unless used in laparoscopic cases where the smoke is contained. 6 However, one study using specifically designed pencil diathermy with in-built channel for smoke extraction, a filter and wall-mounted suction (set to 30 l/min) 13 showed significantly reduced quantity of smoke reaching the surgeon, improved view and reduced noxious smell. Another theatre-based study, to establish health and safety guidelines for surgical smoke, failed to identify any biological or chemical hazards in significant quantities in the theatre environment during selected operations.…”
Section: Discussionmentioning
confidence: 99%
“…HIV proviral DNA has been found in laser plume but it is unclear whether the isolated particles are capable of producing infection [9]. Human papilloma virus has also been documented in the CO 2 laser plume [10,11].…”
Section: Patient Consultationmentioning
confidence: 99%