2011
DOI: 10.1016/j.fertnstert.2011.06.035
|View full text |Cite
|
Sign up to set email alerts
|

Human chorionic gonadotropin from day 2 spent embryo culture media and its relationship to embryo development

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
19
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 33 publications
(21 citation statements)
references
References 22 publications
2
19
0
Order By: Relevance
“…2 The concentration of beta-hCG in spent embryo culture media at different stage 1:day1(2PN), 2:day3(5-8 cells), 3:day5(compact/morula), 4: day5(unexpanded blastocyst),5: day5 (expanded blastocyst), 6:day5(arrest) outgrowth embryo. In 2011, beta-hCG was detected in day2 spent embryo culture media by ELISA [4], whose lowest detectable concentration was 1.4 pg/50 μl (0.255mIU/ml), which is within the range from day1 (0.22mIU/ml) to day 3 (0.55mIU/ml) groups in our study. However, these detection methods could only be employed in research due to the limitations such as more sample volume requirement, suboptimal sensitivity and dynamic range.…”
Section: Discussionsupporting
confidence: 61%
See 3 more Smart Citations
“…2 The concentration of beta-hCG in spent embryo culture media at different stage 1:day1(2PN), 2:day3(5-8 cells), 3:day5(compact/morula), 4: day5(unexpanded blastocyst),5: day5 (expanded blastocyst), 6:day5(arrest) outgrowth embryo. In 2011, beta-hCG was detected in day2 spent embryo culture media by ELISA [4], whose lowest detectable concentration was 1.4 pg/50 μl (0.255mIU/ml), which is within the range from day1 (0.22mIU/ml) to day 3 (0.55mIU/ml) groups in our study. However, these detection methods could only be employed in research due to the limitations such as more sample volume requirement, suboptimal sensitivity and dynamic range.…”
Section: Discussionsupporting
confidence: 61%
“…Compared with other assays reported before [2][3][4], ECLIA could be automated and did not cause radioactive contamination, besides, its analytical precision (mean intra-assay CV: 4.87 %, mean inter-assay CV: 6.25 %) had been improved considerably, which indicated the high dependability in our study. In addition, there was no significant difference between samples in room temperature and stored at −80°C, further supporting the stability of samples and ECLIA.…”
Section: Discussionmentioning
confidence: 55%
See 2 more Smart Citations
“…Some of these molecules were identified by immunological methods, including among others, paf [20,25], IGF-II [26], HLA-G [27], hCG [28], Apolipoprotein A1 [29] and superoxide dismutase-1 [30]. However, there has been considerable debate as to the reliability of some of these measurements.…”
Section: Discussionmentioning
confidence: 99%