Hue-Recognition Strategy-Based Immunoassay Using Functionalized Dendritic Silica Colloids and Gold Nanoclusters for Point-of-Care Testing of C-Reactive Proteins

Abstract: Considering that hue-recognition has drawn increasing research interests for visual detection because of its high accuracy and flexible analysis modalities, the exploration of a rational hue-recognition sensing system is highly demanded. Here, we report a hue-recognition-based lateral flow immunoassay (HLFIA) by ratiometric modulation of emission from two nanoprobes, in which red-emitting ruthenium(II)-doped dendritic silica colloids and green-emitting gold nanoclusters function as reporter and reference, resp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 49 publications
0
2
0
Order By: Relevance
“…The limit of detection (LOD) was calculated to be 0.127 ng/mL. Compared with the reported and commercially available LFIA strips for CRP analysis (Table S2), the current assay performed relatively good. ,, …”
Section: Resultsmentioning
confidence: 87%
See 1 more Smart Citation
“…The limit of detection (LOD) was calculated to be 0.127 ng/mL. Compared with the reported and commercially available LFIA strips for CRP analysis (Table S2), the current assay performed relatively good. ,, …”
Section: Resultsmentioning
confidence: 87%
“…Compared with the reported and commercially available LFIA strips for CRP analysis (Table S2), the current assay performed relatively good. 36,46,47 The design and principle of PSA detection using the UQSN are illustrated in Figure 5a. The anti-PSA AB0105-1 and chicken IgY were labeled with UQSN and fixed on the conjugate pad.…”
Section: Methods Construction Of Test Strips With Uqsn and Analyticalmentioning
confidence: 99%
“…This mode is anticipated to enhance the sensitivity by producing a red signal and simultaneously eliminating the existing green reference intensity on T line, leading to an increased signal/reference (R/G) ratio. [8,58] Meanwhile, it extends the linear detection range by substantial eradication of green reference intensity on T line especially at high antigenconcentration-end, resulting in a prominent increase of R/G value. This partially offsets the general hook effect that causing signal saturation (reaching the plateau) or even decrease.…”
Section: Hue-recognizable Lfia For Visual Detection Of Sars-cov-2 Nuc...mentioning
confidence: 99%