2022 5th International Conference on Renewable Energy and Power Engineering (REPE) 2022
DOI: 10.1109/repe55559.2022.9949524
|View full text |Cite
|
Sign up to set email alerts
|

HR Control Strategy Based on Phase Compensation for LCL Grid-Connected Inverters in Weak Grid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 8 publications
0
1
0
Order By: Relevance
“…The efficient transmission and consumption of renewable energy is an urgent problem to be solved in today's power system. Reasonable power system planning is the key to achieving large-scale grid integration of renewable energy [11] . Before the photovoltaic power station is connected to the grid, it is necessary to conduct reasonable grid connection mode research to ensure that the power flow of each bus node and each line maintains a normal level during the power system operation.…”
Section: Three Grid-connected Modes Of Distributed Photovoltaic Acces...mentioning
confidence: 99%
“…The efficient transmission and consumption of renewable energy is an urgent problem to be solved in today's power system. Reasonable power system planning is the key to achieving large-scale grid integration of renewable energy [11] . Before the photovoltaic power station is connected to the grid, it is necessary to conduct reasonable grid connection mode research to ensure that the power flow of each bus node and each line maintains a normal level during the power system operation.…”
Section: Three Grid-connected Modes Of Distributed Photovoltaic Acces...mentioning
confidence: 99%
“…However, these methods inevitably weaken the grid voltage disturbance suppression and thus deteriorating the steady‐state quality of the grid current. Studies in [21] added phase compensation in the harmonic quasi‐resonant controller, improving the impedance of low‐frequency characteristics without affecting the resonant gain, thus balancing robustness and disturbance suppression ability. In the literature [22], by adding a current feedback loop, an input compensation strategy for the T/4 delayed PLL has been proposed to attenuate the effect of dynamic coupling between the grid impedance and the PLL. Re‐adjustment of PLL characteristics: The literature [23, 24] re‐designed PLL bandwidth using phase margin and short‐circuit ratio (SCR) as constraints, which improved the system stability but sacrificed the current dynamic tracking performance.…”
Section: Introductionmentioning
confidence: 99%
“…However, these methods inevitably weaken the grid voltage disturbance suppression and thus deteriorating the steady‐state quality of the grid current. Studies in [21] added phase compensation in the harmonic quasi‐resonant controller, improving the impedance of low‐frequency characteristics without affecting the resonant gain, thus balancing robustness and disturbance suppression ability. In the literature [22], by adding a current feedback loop, an input compensation strategy for the T/4 delayed PLL has been proposed to attenuate the effect of dynamic coupling between the grid impedance and the PLL.…”
Section: Introductionmentioning