2010
DOI: 10.6026/97320630005255
|View full text |Cite
|
Sign up to set email alerts
|

HPLC Retention time prediction for metabolome analysis

Abstract: Liquid Chromatography Time-of-Flight Mass Spectrometry (LC-TOF-MS) is widely used for profiling metabolite compounds. LC-TOF-MS is a chemical analysis technique that combines the physical separation capabilities of high-pressure liquid chromatography (HPLC) with the mass analysis capabilities of Time-of-Flight Mass Spectrometry (TOF-MS) which utilizes the difference in the flight time of ions due to difference in the mass-to-charge ratio. Since metabolite compounds have various chemical characteristics, the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(13 citation statements)
references
References 6 publications
0
13
0
Order By: Relevance
“…There remain, however, many currently unidentifiable features that were modulated by prebiotic and/or stress. With continued improvements in available reference samples 44 , future work will expand the identification of potential gut derived biomolecular pathways and could facilitate the discovery of additional novel molecules capable of impacting physiology and complex behavior.…”
Section: Discussionmentioning
confidence: 99%
“…There remain, however, many currently unidentifiable features that were modulated by prebiotic and/or stress. With continued improvements in available reference samples 44 , future work will expand the identification of potential gut derived biomolecular pathways and could facilitate the discovery of additional novel molecules capable of impacting physiology and complex behavior.…”
Section: Discussionmentioning
confidence: 99%
“…In untargeted metabolomics, retention time prediction can be used to validate mass-based compound annotations (Hagiwara et al, 2010;Cao et al, 2015). Lipids of the same class elute at similar retention times .…”
Section: Retention Filtermentioning
confidence: 99%
“…QSRR modelling has usually been carried out on a particular class of compounds measured in respective analytical platforms (Sarkhosh et al 2012 ; Tyrkkö et al 2012 ; Meek 1980 ). Only recently has QSRR modelling found an application in metabolomics (Creek et al 2011 ; Hagiwara et al 2010 ) because there is a demand to assign chemical identities to many unknown peaks through improved utilization of retention time, along with mass spectral features.…”
Section: Introductionmentioning
confidence: 99%