2006
DOI: 10.1016/j.physb.2006.05.399
|View full text |Cite
|
Sign up to set email alerts
|

Horizontal ToF-neutron reflectometer REFSANS at FRM-II Munich/Germany: First tests and status

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
47
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 52 publications
(47 citation statements)
references
References 4 publications
0
47
0
Order By: Relevance
“…A heavy load goniometer (up to 200 kg) allows for the manipulation of the heavy and complexly shaped test detector. 54,55 The neutron quantum efficiency measurements were carried out for nat. B 4 C and 10 B 4 C converter coatings with thicknesses of about 1 lm, deposited on Al plates.…”
Section: Experimental: Sample Preparation and Characterizationmentioning
confidence: 99%
See 2 more Smart Citations
“…A heavy load goniometer (up to 200 kg) allows for the manipulation of the heavy and complexly shaped test detector. 54,55 The neutron quantum efficiency measurements were carried out for nat. B 4 C and 10 B 4 C converter coatings with thicknesses of about 1 lm, deposited on Al plates.…”
Section: Experimental: Sample Preparation and Characterizationmentioning
confidence: 99%
“…Using a scattering geometry with 55 incidence angle of the He 2þ ions, the RBS-edges of 12 C, 11 B, and 10 B can be resolved better for a quantitative determination of their relative amounts. In non-normal incidence, the travel path of the He 2þ -ions within the B 4 C layer, and thus the scattering probability of the He 2þ -ion on 10 B, 11 B, and 12 C, is increased (same principle as for increasing the neutron efficiency of a converter layer).…”
Section: B Depth Profile Investigations Of Boron Carbide Coatingsmentioning
confidence: 99%
See 1 more Smart Citation
“…A dedicated reflectometer REFSANS [44] to measure also in grazing incidence small angle neutron scattering (GISANS) and diffraction (GID) has been installed at FRM II. REFSANS combines features of a TOF reflectometer and a TOF SANS instrument, to allow in particular the investigation of planar membranes and monolayers at liquid interfaces to study later aggregation and ordering in fluid self-assembled systems.…”
Section: Biomembranes and Surface Interactionsmentioning
confidence: 99%
“…In order to improve data quality, some new methods were proposed. A smart strategy is taken at the REFSANS instrument at Heinz Maier-Leibnitz zentrum [26] . The data are acquired in list mode, all neutrons are saved with their time-of-flight, and wavelength conversion is performed later [27] .…”
Section: Introductionmentioning
confidence: 99%