Background High blood pressure (BP) is the commonest modifiable cardiovascular risk factor, yet its monitoring remains problematic. Wearable cuffless BP devices offer potential solutions; however, little is known about their validity and utility. We aimed to systematically review the validity, features and clinical use of wearable cuffless BP devices. Methods We searched MEDLINE, Embase, IEEE Xplore and the Cochrane Database till December 2019 for studies that reported validating cuffless BP devices. We extracted information about study characteristics, device features, validation processes, and clinical applications. Devices were classified according to their functions and features. We defined devices with a mean systolic BP (SBP) and diastolic BP (DBP) biases of <5 mmHg as valid as a consensus. Our definition of validity did not include assessment of device measurement precision, which is assessed by standard deviation of the mean difference- a critical component of ISO protocol validation criteria. Study quality was assessed using the QUADAS-2 tool. A random-effects model meta-analysis was performed to summarise the mean biases for systolic and diastolic BP across studies. Results Of the 430 studies identified, 16 studies (15 devices, 974 participants) were selected. The majority of devices (81.3%) used photoplethysmography to estimate BP against a reference device; other technologies included tonometry, auscultation and electrocardiogram. In addition to BP and heart rate, some devices also measured night-time BP (n=5), sleep monitoring (n=3), oxygen saturation (n=3), temperature (n=2) and electrocardiogram (n=3). Eight devices showed mean biases of <5 mmHg for SBP and DBP compared to a reference device and three devices were commercially available. The meta-analysis showed no statistically significant differences between the wearable and reference devices for SBP (pooled mean difference=3.42 mmHg, 95%CI -2.17, 9.01, I2 95.4%) and DBP (pooled mean=1.16 mmHg, 95%CI -1.26, 3.58, I2 87.1%). Conclusion Several cuffless BP devices are currently available using different technologies, offering the potential for continuous BP monitoring. The variation in standards and validation protocols limited the comparability of findings across studies and the identification of the most accurate device. Challenges such as validation using standard protocols and in real-life settings must be overcome before they can be recommended for uptake into clinical practice.
Background High blood pressure (BP) is the commonest modifiable cardiovascular risk factor, yet its monitoring remains problematic. Wearable cuffless BP devices offer potential solutions; however, little is known about their validity and utility. We aimed to systematically review the validity, features and clinical use of wearable cuffless BP devices. Methods We searched MEDLINE, Embase, IEEE Xplore and the Cochrane Database till December 2019 for studies that reported validating cuffless BP devices. We extracted information about study characteristics, device features, validation processes, and clinical applications. Devices were classified according to their functions and features. We defined devices with a mean systolic BP (SBP) and diastolic BP (DBP) biases of <5 mmHg as valid as a consensus. Our definition of validity did not include assessment of device measurement precision, which is assessed by standard deviation of the mean difference- a critical component of ISO protocol validation criteria. Study quality was assessed using the QUADAS-2 tool. A random-effects model meta-analysis was performed to summarise the mean biases for systolic and diastolic BP across studies. Results Of the 430 studies identified, 16 studies (15 devices, 974 participants) were selected. The majority of devices (81.3%) used photoplethysmography to estimate BP against a reference device; other technologies included tonometry, auscultation and electrocardiogram. In addition to BP and heart rate, some devices also measured night-time BP (n=5), sleep monitoring (n=3), oxygen saturation (n=3), temperature (n=2) and electrocardiogram (n=3). Eight devices showed mean biases of <5 mmHg for SBP and DBP compared to a reference device and three devices were commercially available. The meta-analysis showed no statistically significant differences between the wearable and reference devices for SBP (pooled mean difference=3.42 mmHg, 95%CI -2.17, 9.01, I2 95.4%) and DBP (pooled mean=1.16 mmHg, 95%CI -1.26, 3.58, I2 87.1%). Conclusion Several cuffless BP devices are currently available using different technologies, offering the potential for continuous BP monitoring. The variation in standards and validation protocols limited the comparability of findings across studies and the identification of the most accurate device. Challenges such as validation using standard protocols and in real-life settings must be overcome before they can be recommended for uptake into clinical practice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.