2020
DOI: 10.1016/j.jpba.2020.113573
|View full text |Cite
|
Sign up to set email alerts
|

HILIC-MS determination of dimethylamine in the active pharmaceutical ingredients and in the dosage forms of metformin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…The LOD of DMA is about 1000 times lower than headspace gas chromatography method (930 μg/L) [ 17 ]. The reported LOD of DMA is 5.4 μg/L by HPLC with diode array detection after derivatization with halonitrobenzenes, and 0.75 μg/L by hydrophilic interaction chromatography coupled with mass spectrometry detection (HILIC-MS) [ 11 , 18 ]. The LOD of DMA using our method is close to HILIC-MS method without the need of a high-cost mass spectrometer.…”
Section: Resultsmentioning
confidence: 99%
“…The LOD of DMA is about 1000 times lower than headspace gas chromatography method (930 μg/L) [ 17 ]. The reported LOD of DMA is 5.4 μg/L by HPLC with diode array detection after derivatization with halonitrobenzenes, and 0.75 μg/L by hydrophilic interaction chromatography coupled with mass spectrometry detection (HILIC-MS) [ 11 , 18 ]. The LOD of DMA using our method is close to HILIC-MS method without the need of a high-cost mass spectrometer.…”
Section: Resultsmentioning
confidence: 99%
“…Thus, N , N ‐dimethylaniline belongs to the class of pH‐dependent analytes (Liigand et al, 2021). Similarly, the quantitation of dimethylamine in metformin drug products was carried out using a mobile phase containing ammonium formate pH 4.8 in ESI + (Douša & Jireš, 2020).…”
Section: Ms‐based Methods In the Analysis Of Small‐molecule Chemical ...mentioning
confidence: 99%
“…1,7-Diaminoheptane (Dah) (1 μM × 0.1 mL) was added to 1 mL of extract as an internal standard. Diamines and aminoamides in the extractants were analyzed by HILIC-ESI-MS/MS (LCMS-8040, Shimadzu, Kyoto, Japan). Chromatographic separation was performed with a HILIC column (HILICpak VC-50 2D, Shodex, Tokyo, Japan) and an eluent of 0.2 M formic acid at a flow rate of 0.20 mL/min in isocratic mode. The eluted target compounds were detected with the mass spectrometer by selected reaction monitoring (SRM) (see Table S1 in the Supporting Information for SRM settings).…”
Section: Methodsmentioning
confidence: 99%