2017
DOI: 10.1016/j.aca.2016.11.068
|View full text |Cite
|
Sign up to set email alerts
|

Highly sensitive quantification for human plasma-targeted metabolomics using an amine derivatization reagent

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 18 publications
(12 citation statements)
references
References 52 publications
1
11
0
Order By: Relevance
“…The plasma samples were deproteinized using acetonitrile at a final concentration of 80% before the measurements. The concentrations of the plasma amino acids and their related metabolites were measured using high‐performance liquid chromatography‐electrospray ionization mass spectrometry, followed by pre‐column derivatization using previously described analytical methods …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The plasma samples were deproteinized using acetonitrile at a final concentration of 80% before the measurements. The concentrations of the plasma amino acids and their related metabolites were measured using high‐performance liquid chromatography‐electrospray ionization mass spectrometry, followed by pre‐column derivatization using previously described analytical methods …”
Section: Methodsmentioning
confidence: 99%
“…The concentrations of the plasma amino acids and their related metabolites were measured using high-performance liquid chromatography-electrospray ionization mass spectrometry, followed by pre-column derivatization using previously described analytical methods. [21][22][23]…”
Section: Geriatric Depressive Symptomsmentioning
confidence: 99%
“…Tryptophan was analyzed and quantified using LC‐MS/MS (Agilent 1290 Infinity series liquid chromatography system; Agilent Technologies) coupled to an API4000 mass spectrometer (AB Sciex). Kynurenine, 5‐HTP, and serotonin were analyzed and quantified using LC‐MS/MS (ACQUITY UPLC system; Waters) coupled to a 5500 QTRAP mass spectrometer (AB Sciex) as described previously …”
Section: Methodsmentioning
confidence: 99%
“…The concentrations of Trp and ILA in human plasma were found to be much higher than those of other metabolites, moreover, their peak intensities were saturated. To solve this problem, we selected the isotopic ion (m+1) of Trp and ILA for determination [25,27]. The extracted mass chromatograms under optimized analytical condition are shown in Fig.…”
Section: Optimization Of Lc-ms/ms Conditionsmentioning
confidence: 99%
“…Various methods of analyzing Trp metabolites have been reported [17][18][19][20][21][22][23][24]. In our previous studies, we have developed analytical methods to quantify amino acids and their metabolites in human plasma using pre-column derivatization with a 3-aminopyridyl-N-hydroxy succinimidyl carbamate (APDS) reagent and liquid chromatography tandem mass spectrometry (LC-MS/MS) [25]. However, some Trp metabolites could not be analyzed using the APDS reagent because of their lack of amino groups.…”
Section: Introductionmentioning
confidence: 99%