2017
DOI: 10.1007/s11814-017-0224-9
|View full text |Cite
|
Sign up to set email alerts
|

Highly sensitive glucose biosensor using new glucose oxidase based biocatalyst

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 50 publications
(15 citation statements)
references
References 32 publications
0
15
0
Order By: Relevance
“…Although the superior properties of CNT, such as excellent electric conductivity and chemical stability, may promote the desirable redox reaction of KI in catholyte, EE of AORFBs using MWCNT@CF and CA-CNT@CF was lower than that of AORFB using pristine CF. [53][54][55][56] This is because the mass transfer and electron transfer resistance of MWCNT@CF and CA-CNT@CF are too high. These drawbacks are probably because the amount and ratio of Nafion solution and catalysts applied are not optimized.…”
Section: The Performances Of Aorfbs Using Nq-oh and Ki As Redox Couplementioning
confidence: 99%
“…Although the superior properties of CNT, such as excellent electric conductivity and chemical stability, may promote the desirable redox reaction of KI in catholyte, EE of AORFBs using MWCNT@CF and CA-CNT@CF was lower than that of AORFB using pristine CF. [53][54][55][56] This is because the mass transfer and electron transfer resistance of MWCNT@CF and CA-CNT@CF are too high. These drawbacks are probably because the amount and ratio of Nafion solution and catalysts applied are not optimized.…”
Section: The Performances Of Aorfbs Using Nq-oh and Ki As Redox Couplementioning
confidence: 99%
“…In the analyses performed, it has been shown that high-performance glucose biosensor can be developed with excellent properties such as high catalytic activity, and high chemical stability of CNTs-modified hybrid material. Additionally, it has been proven that biosensors can be used effectively for hypoglycemia and diabetes real patients [85].…”
Section: Glucose Biosensors Based On Functionalized Cntsmentioning
confidence: 99%
“…In this condition, protons and electrons from GOR were used for the reduction reaction of FAD (FAD + 2H + + 2e − → FADH 2 ) and made the background current shifted upward. At the same time, GOx converted the oxygen from glucose to H 2 O 2 (O 2 + 2H + + 2e − → H 2 O 2 ) [32]. The changes in current, due to these reactions, are usually the signals detected by glucose biosensors.…”
Section: Catalyst Structurementioning
confidence: 99%