2018
DOI: 10.1149/2.0551807jes
|View full text |Cite
|
Sign up to set email alerts
|

Highly Sensitive Carbon Based Sensors Using Zinc Oxide Nanoparticles Immobilized Multiwalled Carbon Nanotubes for Simultaneous Determination of Desvenlafaxine Succinate and Clonazepam

Abstract: Carbon paste electrode modified with zinc oxide nano particles immobilized on multi-walled carbon nano tubes (MWCNTs/ZnO-NPs/CPE) was exploited for the simultaneous determination of Desvenlafaxine succinate (DVS) and Clonazepam (CLZ) in drug substance and combined drug products as well as in spiked human urine. The electrochemical response characteristics of the modified electrode toward DVS and CLZ were investigated by cyclic and differential pulse voltammetry (CV and DPV). The cyclic voltammograms showed wel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 28 publications
0
13
0
Order By: Relevance
“…The electroactive surface area of the electrodes were calculated using Randles-Sevcik equation for for a reversible process given as: 31,32 I 2.69 10 An D C…”
Section: Resultsmentioning
confidence: 99%
“…The electroactive surface area of the electrodes were calculated using Randles-Sevcik equation for for a reversible process given as: 31,32 I 2.69 10 An D C…”
Section: Resultsmentioning
confidence: 99%
“…In another study, Rizk et al applied the CPE modified with zinc oxide NPs immobilized on the MWCNTs (MWCNTs/ZnONPs/CPE) to simultaneously determine clonazepam (CLZ) and desvenlafaxine succinate (DVS) in the drug materials, the combined drug products, and in spiked human urine [ 31 ]. Moreover, DPV and CV were used to investigate electrochemical response features of the modified electrode toward DVS and CLZ.…”
Section: Electrochemical Detection Of Venlafaxinementioning
confidence: 99%
“…Consequently, a satisfactory linear association was observed between the peak current and concentration in ranges of 0.66 to 8.42 μg/mL and 0.39 to 7.70 μg/mL for DVS and CLZ with DPV. Finally, this procedure was substantially utilized to estimate CLZ and DVS in the spiked human urine [ 31 ]. Many characteristics of the CPE in VEN electrochemical detection are summarized in Table 1 .…”
Section: Electrochemical Detection Of Venlafaxinementioning
confidence: 99%
“…drugs. 72 MWCNTs are also being developed for the simultaneous detection targets with overlapping electrochemical oxidation peaks. 73 Functionalized carbon black and Nickel Sulfide have been used to detect Glucose in a non-enzymatic sensor.…”
Section: Urea Diet Starvationmentioning
confidence: 99%