“…blank. Although others have reported a similar performance using gold electrodes in a standard three-electrode cell or improved sensitivity using a combination of carbon electrodes and nanomaterials, as presented in Table 7, this work was the first in which such a detection was demonstrated using a commercially available gold SPE for the electrochemical immunosensor in bodily fluids [47,[58][59][60][61][62][63][64][65][66]. The logistic regression equation is given as 𝐼 = 𝐴 + 𝐵 × ln (𝑥), where A is 228 and B is 202, with an r 2 = 0.9822.…”
Section: Sensing Platform Evaluationmentioning
confidence: 70%
See 1 more Smart Citation
“…blank. Although others have reported a similar performance using gold electrodes in a standard three-electrode cell or improved sensitivity using a combination of carbon electrodes and nanomaterials, as presented in Table 7, this work was the first in which such a detection was demonstrated using a commercially available gold SPE for the electrochemical immunosensor in bodily fluids [47,[58][59][60][61][62][63][64][65][66]. The logistic regression equation is given as 𝐼 = 𝐴 + 𝐵 × ln (𝑥), where A is 228 and B is 202, with an r 2 = 0.9822.…”
Section: Sensing Platform Evaluationmentioning
confidence: 70%
“…It shows a linear relationship between the steady-state current and the logarithmic values of the antigen concentration in the range from 3.5 ng/mL to 80 ng/mL with a theoretical detection limit (LOD) of 1.0 ng/mL, estimated as the mean blank level + 3 × standard deviation of the blank. Although others have reported a similar performance using gold electrodes in a standard three-electrode cell or improved sensitivity using a combination of carbon electrodes and nanomaterials, as presented in Table 7, this work was the first in which such a detection was demonstrated using a commercially available gold SPE for the electrochemical immunosensor in bodily fluids [47,[58][59][60][61][62][63][64][65][66].…”
Section: Sensing Platform Evaluationmentioning
confidence: 71%
“…Lipocalin 2 (LCN 2) is a protein with a molecular weight of 25 kDa that mainly exists in the kidney, liver, epithelial cells, and other tissues. LCN 2 is considered a promising biomarker for the prediction of kidney-related diseases 111 . Kao et al 111 prepared NiO NPs-modified CeCuO x (NiO NPs/CeCuO x ) thin film-based biosensors.…”
Section: Application Of Electrochemical Protein Sensors In the Detect...mentioning
confidence: 99%
“…LCN 2 is considered a promising biomarker for the prediction of kidney-related diseases 111 . Kao et al 111 prepared NiO NPs-modified CeCuO x (NiO NPs/CeCuO x ) thin film-based biosensors. First, CeCuO x and NiO were deposited successively on a silicon substrate to prepare the electrode, and then, anti-LCN 2 was immobilized on its surface to detect the presence of LCN 2.…”
Section: Application Of Electrochemical Protein Sensors In the Detect...mentioning
confidence: 99%
“…X-ray diffraction (XRD) is commonly employed to elucidate the perovskite crystalline structure. Ideally, perovskites of the form ABX 3 are arranged into a cubic cell, where the atoms are just touching each other, and the B-X distance is equal to a/2 and the A-X distance is 2a/2, where a is the cube unit cell length and the relationship between radii of ions holds RA + Rx = 2RB + Rx [113][114][115]. However, distorted structures with tetragonal, rhombohedral, or orthorhombic symmetry have been found, mainly arising from smaller A ions that induce a tilting of the BX 6 octahedra to optimize A-X bonding.…”
Section: Sensing Of Hydrogen Peroxide (H 2 O 2 )mentioning
confidence: 99%