2013
DOI: 10.1016/j.snb.2013.06.020
|View full text |Cite
|
Sign up to set email alerts
|

Highly sensitive and selective detection of dopamine in the presence of ascorbic acid at graphene oxide modified electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

10
119
3
3

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 301 publications
(135 citation statements)
references
References 45 publications
10
119
3
3
Order By: Relevance
“…The detection limit was smaller than some previous reported works such as Ni/Al layered double hydroxide modified carbon ionic liquid electrode (5.0× 10 -6 mol L -1 ), [29] PtAu hybrid film modified GCE (5.0× 10 -6 mol L -1 ), [30] and GR modified GCE (2.64× 10 -6 mol L -1 ), [31] GR and Au nanoparticles modified GCE (1.86× 10 -6 mol L -1 ), [32] TiO2-GR modified GCE (2.0× 10 -6 mol L -1 ), [33] and graphene oxide modified GCE (0.27× 10 -6 mol L -1 ). [34] So the presence of NG on the GCE surface exhibited excellent electrocatalytic activity to the oxidation of DA with increased sensitivity.…”
Section: Calibration Curvementioning
confidence: 96%
“…The detection limit was smaller than some previous reported works such as Ni/Al layered double hydroxide modified carbon ionic liquid electrode (5.0× 10 -6 mol L -1 ), [29] PtAu hybrid film modified GCE (5.0× 10 -6 mol L -1 ), [30] and GR modified GCE (2.64× 10 -6 mol L -1 ), [31] GR and Au nanoparticles modified GCE (1.86× 10 -6 mol L -1 ), [32] TiO2-GR modified GCE (2.0× 10 -6 mol L -1 ), [33] and graphene oxide modified GCE (0.27× 10 -6 mol L -1 ). [34] So the presence of NG on the GCE surface exhibited excellent electrocatalytic activity to the oxidation of DA with increased sensitivity.…”
Section: Calibration Curvementioning
confidence: 96%
“…where i pc is the reduction peak current of K 3 In order to explore the effect of electrocatalytic activity on the response peak current, the peak current densities are estimated by dividing by their electrochemical area, aiming to exclude the influence of the electrochemical active area. The peak current densities (J a ) of MnO 2 NWs-RGO/GCE, MnO 2 NRs-RGO/GCE, and MnO 2 NTs-RGO/GCE are listed in the fourth column in Table 1.…”
Section: Electrochemical Active Area Of Mno 2 -Rgo/gcesmentioning
confidence: 99%
“…An abnormal level of dopamine may cause several central nervous system diseases such as depression, anxiety, schizophrenia, and Parkinson's disease [2][3][4][5]. Therefore, it is of great significance to detect dopamine accurately at a physiological level in the earlier prevention and clinical diagnosis of these neurological diseases.…”
Section: Introductionmentioning
confidence: 99%
“…A linear dependence of peak potential on pH of the supporting electrolyte was obtained following a linear equation: E/mV = 787.4 -62.64 pH; R 2 = 0.997. The peak potential at 25 ºC is expressed as [32]: E p = Eº -(m/n) 59 pH (2) where, Eº is the standard potential, m and n are the number of protons and electrons respectively. Since the plot of E pa (mV) vs. pH gave a slope of 62.64 mV/pH which is close to the expected value of 59 mV/pH, we can say m/n is 1.…”
Section: Effect Of Supporting Electrolyte and Phmentioning