Highly Sensitive and Precise Measurement of Helium Isotopes Using a Mass Spectrometer with Double Collector System.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
60
0

Year Published

2002
2002
2019
2019

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 78 publications
(60 citation statements)
references
References 0 publications
0
60
0
Order By: Relevance
“…In contrast, a modified VG5400 machine (MS-III) and a similar instrument with split tube double collectors (MS-IV) were used at the Laboratory for Earthquake Chemistry at The University of Tokyo. The precise description of the modifications to the MS-IV and of the measurements using the MS-IV were given by Sumino et al (2001).…”
Section: Analytical Methods and Resultsmentioning
confidence: 99%
“…In contrast, a modified VG5400 machine (MS-III) and a similar instrument with split tube double collectors (MS-IV) were used at the Laboratory for Earthquake Chemistry at The University of Tokyo. The precise description of the modifications to the MS-IV and of the measurements using the MS-IV were given by Sumino et al (2001).…”
Section: Analytical Methods and Resultsmentioning
confidence: 99%
“…Elemental abundances of He and Ne, and He isotope composition of the gas samples collected in a 50 cm 3 lead glass bottle with high vacuum stopcocks were analyzed in the laboratory of the Geochemical Research Center, The University of Tokyo. A magnetic-sector mass spectrometer VG 5400 was used for the analysis following the methodology described by Sumino et al (2001).…”
Section: Procedures and Methodsmentioning
confidence: 99%
“…By using an electrical circuit and the computer program written in HP-Basic on a Microso Windows PC, which is based on the programs reported by Nagao et al 15) and Sumino et al, 16) an excitation current for the main magnet can be set and maintained at a given value by the program to obtain a mass spectrum by scanning the magnetic eld. …”
Section: Controller For the Ion Sourcementioning
confidence: 99%
“…He-MS is equipped with a noble gas preparation line ConstructIon oF a NewLY DesIgneD SmaLL-SIze MS For He IsotoPe AnaLYsIs similar to those described in Nagao et al 15) and Sumino et al, 16) in which noble gases are puri ed by chemically removing reactive gases with titanium-zirconium getters heated at about 800°C, He and Ne are then separated from Ar, Kr and Xe by adsorbing the latter on charcoal traps cooled at liquid nitrogen temperature, and nally the He is separated from Ne by adsorbing the Ne on a sintered stainless steel trap (Cryogenic trap) cooled at about 20 K. e puri ed He in the line is introduced into He-MS for determining the 3 He/ 4 He ratio and the amount of 4 He. Next, Ne is desorbed from the Cryogenic trap at approximately 50 K, and then introduced into He-MS for measuring amount of 20 Ne.…”
Section: Noble Gas Preparation Linementioning
confidence: 99%
See 1 more Smart Citation