2015
DOI: 10.1016/j.electacta.2015.03.222
|View full text |Cite
|
Sign up to set email alerts
|

Highly selective detection of cellular guanine and xanthine by polyoxometalate modified 3D graphene foam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 92 publications
(90 reference statements)
0
7
0
Order By: Relevance
“…3DG was synthesized according to previous work via CVD growth using ethanol as carbon source. 2,36,37 3D structure of graphene is clearly shown in Fig. 1a, which will facilitate the mass transfer during our next heterogeneous catalytic reaction.…”
Section: Resultsmentioning
confidence: 94%
See 1 more Smart Citation
“…3DG was synthesized according to previous work via CVD growth using ethanol as carbon source. 2,36,37 3D structure of graphene is clearly shown in Fig. 1a, which will facilitate the mass transfer during our next heterogeneous catalytic reaction.…”
Section: Resultsmentioning
confidence: 94%
“…3DG is synthesized according to our previous method. 36,37 3DG was obtained by etching away nickel foam in 1 M FeCl 3 aqueous solution (1 M HCl). 3DG@Au: 3DG foam (1 Â 1 cm) was soaked in 2 mL water containing 1 mg mL À1 HAuCl 4 $3H 2 O, and the mixture was incubated for 1 h at r.t. 100 mL 0.1 M NaBH 4 was injected drop by drop into the above solution to initiate the formation of Au nanostructure.…”
Section: Methodsmentioning
confidence: 99%
“…Figure shows the quantitative calibration plot (in presence of different concentration values of G, performed by DPV and the corresponding quantitative parameters are reported on Table . FB‐SPE shows the widest range of linearity for the analytical responses to the concentration of G; a good sensitivity (lower than that exhibited by the as reported Graphitized Mesoporous Carbon (GMC) modified GCE, probably for the highest surface nominal area exhibited by the GMC electrodic materials) and the lowest detection limit, if compared with other electrochemical devices reported in literature , and summarized in Table . Also the FB‐SPE show the best intra‐ and inter‐electrodes reproducibility, and the fastest response time (useful to carry out a real time analysis of a large number of samples during the same day, applying disposable, miniaturized and partially automated electrochemical sensors, modified with functionalized fullerenes).…”
Section: Resultsmentioning
confidence: 99%
“…In 2014, two new modified electrode have been prepared by us, in one of which the overlapped signal of A/H was further separately detected as two signals, at the same time, the overlapped signal of G/X can't be separated [23]. Similarly, the overlapped signal of G/X was also separately detected as two signals with the overlapped signal of A/H in the other modified electrode [24]. However, the two overlapped signals have been unable to be separated completely as four independent signals.…”
Section: Introductionmentioning
confidence: 99%